Default pre-delivery time control settings:
Warning: Changing the above settings may damage the battery and charging circuit.
Period
Light Ratio
Idle Ration
First Time
9 Hours
10%
0%
Second Time
9 Hours
10%
0%
4.2 Default Settings
4.3 Remote Control
1.
Take the solar panel outside and wait for it to charge in the sunlight for at least one hour.
2. Use the remote control and point it towards the black sensor at the back of the solar panel and
press
Power
. The remote control will be powered up. It will then try to connect the solar panel.
•
If connection is successful, the LCD will show “Read OK”.
•
If connection fails, the LCD will show “Disconnect”
Note: Direct sunlight can interfere with the transmission. The sensitivity of the transmitter is
higher when in dark environment.
Important:
Do not change the device number otherwise it may not work properly.
The device number for this system is:
PCC_G05
3. Press and hold the
ON
button to enable the solar light.
Fig. 4.3a
Solar panel remote control
Fig. 4.3b
Remote control LCD
Battery type:
Li_PO for both
SSL-B50
and
SSL-B60
Battery and charging settings:
(DO NOT ADJUST)
S
S
L-B
50
S
S
L-B
6
0
Overcharge Protection Voltage (Boost Charge):
14.
4
V
28.
8
V
Cut-off Voltage (Voltage Low):
1
0.5
V
2
1
.0V
Start Up Voltage (Recover Voltage):
12.0V
24.0V