    Feed through header for Generator I/O

Use the 3-pin feed through header for Generator dry contact connec-

tions. It is recommended to install this feed through header in Enpower 

even if you are not currently planning to use the Generator feature. 

This ensures that the header will not get lost. Use pins 1 and 3 on the 

header for inserting wires. Supports AWG 28 to AWG 16 wire sizes. 

Torque for tightening the screws on the top is 0.22 N•m (1.9 lb•in) to 

0.25 N•m (2.2 lb•in).

2. Tighten these screws to 

hold the wires in place

3. Insert into I/O port on En-

power in this orientation

Insert wires in these 

terminals

The Enphase Enpower Lit Kit contains screws, feed through headers, filler plates and labels that enable you to properly install Enpower and configure 

features such as PCS (power control system), load control with auxiliary contacts, and generator integration. 

  Q U I C K

  I N S T A L L  

G U I D E

 

Model number: EP200G-LITKIT 

Instructions to use the 

Enphase Enpower 

Literature Kit

 (Lit Kit) 

The contents of the Lit Kit and how to use them

 

are

 

described below:

  

     8-32 screw

Use the 8-32 screw from the lit kit to secure the mains breaker (not the load 

breaker) to Enpower. Use a T20 drive to tighten the 8-32 screw to 1.5 N•m 

(13.3 lb•in). Do not use any other screw.

Install 8-32 screw 

with 1.5 N.M 

torque 

    Feed through header for I/O-1 and I/O-2

Use the two 4-pin feed through headers shipped with the lit kit for 

making auxiliary contact connections 

for load control and excessive 

PV shedding.

 It is recommended to install these feed through headers 

in Enpower even if you are not currently planning to use load control 

and PV shedding features. This ensures that these headers will not get 

lost. Supports AWG 28 to AWG 16 wire sizes. Torque for tightening the 

screws on the top is 0.22 N•m (1.9 lb•in) to 0.25 N•m (2.2 lb•in).

    Lit Kit label 

       If Enpower is installed as service equipment:

•  Connect a grounding electrode conductor to the grounding bar. 
•  From the lit kit, place the label “GROUNDING ELECTRODE TERMI-

NAL” adjacent to the grounding bar. 

•  From the lit kit, place the label “SUITABLE FOR USE AS SERVICE 

EQUIPMENT”/ “MAIN SERVICE DISCONNECT” on the deadfront 

near the main breaker/service disconnect. 

•   If Enpower is not used as service equipment, these labels should 

not be used. 

© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enpower smart switch, Encharge storage system, Envoy, Combiner, Microinverter, 

Installer Toolkit, Enlighten and other trademarks or service names are trademarks of Enphase Energy, Inc. Data subject to change. 04-16-2021

rev.

Modificaton

ECN

Date Drawing Approved

Material

Hardness

Finish

Description

Stainless steel A2-70

Customer Code

Customer P/N

& drawing no.

Drawing No.

Article No.

Scale

Size

UNSPECIFIED TOLERANCES

Version

QP Level

Q2

02

All dimensions are in inch

Third angle projection

00 Created

N/A

2019/12/4 Mary He Don Tang

A4

Not ot Scale

6358144

Business Unit

BOC

Important Disclaimer

The technical recommendations contained in this publication are necessarily of a general nature and should not be relied on for specific applications without first

securing competent advice. Whilst Bossard has taken all reasonable steps to ensure the information contained herein is accurate and current, Bossard does not

warrant the accuracy or completeness of the information and does not accept liability for errors or omissions.

Hexalobular socket pan head machine

screw #8-32UNCX0.63

0.306-0.322

0.105-0.115

0.63 

0

-0.03

#8-32UNC

Hexalobular Drive X20

Note:

1.Without burr,Sharp edges or other disfigurements.

2.The part is RoHS compliance.

3. Refer ASME B18.6.3

.

4. Comply with thread locking standard IFI 124.

Passivation

02

Q2

Mary He
Mary He

2019/12/9

6358144

0.055-0.070

01 Add nylon patch.

N/A

2019/12/5 Mary He Don Tang

Nylon blue patch (half circle

90° ~180° ), cover 4-6

threads, 1-2 lead thread

free of locking material

02

 Change nylon patch standard to IFI 124 for inch screw, was IFI 524.

N/A

2019/12/9 Mary He Don Tang

730-00305

1. Insert wires here

4. Tighten these screws to se-

cure the feed-through header 

to the I/O ports on Enpower

Feed through headers for 

I/O-1 and I/O-2

Feed through header 

for Generator I/O

2

3

4

1

Отзывы: