AC Combiner Box Installation
Envoy-S LED States
LED
State
Description
All
Flashing amber in unison
The Envoy-S is booting up
Flashing green sequentially
Software upgrade in progress
Network
Communications
Solid green
Communicating with Enlighten
Flashing green
WPS connection in progress, or Envoy-S is attempting to
connect to Enlighten
Solid amber
Local network connection only
Off
No network connection
AP mode
Solid green
AP mode enabled:
Envoy Wi-Fi network available
Off
AP mode disabled:
Envoy Wi-Fi network unavailable
Power
production
Solid green
All communicating microinverters are producing
Flashing green
Microinverter upgrade in progress
Solid Amber
At least one microinverter is not producing
Off
Microinverters are not communicating
(low light or night time)
Device
Communications
Solid Green
All microinverters are communicating
Flashing Green
Device scan in progress
Solid Amber
At least one microinverter is not communicating
Off
Microinverters are not communicating
(low light or night time)
Microinverter Detection Issues
Troubleshoot power line communication issues as follows.
Issue: Device Communications LED is Solid Amber
If the Device Communications LED lights solid amber, it may be a result of low light levels. If there is not
enough sunlight to power up the microinverters, they cannot communicate with the Envoy. If there is
sufficient daylight for the microinverters to power up, the issue may be that the Envoy is having difficulty
communicating over the power lines. To troubleshoot this issue:
•
Check the Installer Toolkit mobile app to see which microinverters are not communicating.
•
Check that the circuit breaker(s) for the PV array are in the “ON” position.
•
Verify that the PV modules are connected to the microinverters.
•
Verify the PV module DC voltage is within the allowable range for the microinverter.
Issue: Installer Toolkit Detects Fewer Microinverters than Expected
The
Microinverters detected
count is an indication of the number of online microinverters producing power,
reporting in to the Envoy, and not having any error conditions. If this number is lower than expected, it may
indicate that the Envoy is not done scanning/discovering the entire array. Alternatively, it may indicate that
the Envoy is having difficulty communicating over the power lines. It could also be a result of low light levels
or that the PV module voltage is too low for the microinverter to power up. To troubleshoot the issue: