Position the Enphase Engage™ Cable

a. 

Plan the cable length to allow drop connectors on 
the Engage Cable align to with each PV module. 
Allow extra length for slack, cable turns and any 
obstructions.

b. 

Cut a length of Engage Cable to meet your 
planned needs.

c. 

Lay out the cabling along the installed racking for 
the AC branch circuit.

Install an AC Junction Box

a. 

Install an appropriately rated, off-the-shelf junction 
box at a suitable location on the racking.

b. 

Provide an AC connection from the AC junction 
box back to the electricity network connection us-
ing equipment and practices as required by local 
jurisdictions.

See notes in 

Step Details

.

2

Attach the Microinverters to the PV Racking

a. 

Mark the approximate centers of each PV  
module on the PV racking. See notes in 

Step 

Details

.

b. 

Mount the microinverter under the PV module, 
away from rain and sun. Allow a minimum of  
1.9 cm (0.75”) between the roof and the  

microinverter. Also allow 1.3 cm (0.50”) between 

the back of the PV module and the top of the 

 

microinverter. 

Note:

 Install the microinverter as shown, with the 

contoured side up. Failure to do so could allow the 
microinverter to come in contact with the PV module 
back sheet.

Dress the Cable

a. 

Use cable clips or tie wraps to attach the cable to 
the racking.

b. 

Dress any excess cabling in loops so that it does 
not contact the roof. Do not form loops smaller 
than 4.75 inches (12 cm) in diameter.

Keep the drop 
connector 
release holes 
clear and  
accessible.

cable clip

release holes

5

4

Create an Installation Map

Create a paper installation map to record microin-
verter serial numbers and position in the array.

a. 

Peel the removable serial number label from each 

microinverter and affix it to the respective location 

on the paper installation map.

b. 

Peel the label from the Envoy and affix it to the 

installation map.

Always keep a copy of the installation map for your 
records

affix 

 

serial number 

labels

Do not mount the microinverter in a  

position that allows long-term exposure to 

direct sunlight or in a vertical orientation 

that allows water to collect in the cable  

connector recess.

c. 

Torque the microinverter fasteners as fol-
lows.  
Do not over torque:

•  5 N m (45-50 in-lbs) for 6 mm (1/4”) 

hardware

•  9 N m (80-85 in-lbs) for 8 mm (5/16”) 

hardware

This side up

Содержание Enphase S Series

Страница 1: ... is correct and that none of the AC or DC wires are pinched or damaged Ensure that all AC junction boxes are properly closed WARNING Risk of electric shock Risk of fire Do not exceed the maximum number of microinverters in an AC branch circuit as listed in this guide You must protect each microinverter AC branch circuit with a 20A maxi mum breaker WARNING Do not connect Enphase Microinverters to t...

Страница 2: ...sk of electric shock Risk of fire Do not leave AC connectors on the Engage Cable uncovered for an extended period If you do not replace the microin verter immediately you must cover any unused connec tor with a sealing cap Sealing caps may not be reused WARNING Risk of electric shock Risk of fire Make sure protective sealing caps have been installed on all unused AC connectors Unused AC connectors...

Страница 3: ...oy S Enphase Installer Toolkit mobil app optional but strongly recommended Engage Cable single phase 240 VAC or three phase 208 VAC Cable clips Sealing caps as needed for any unused drops on the Engage Cable Terminators as needed one needed at the end of each AC branch circuit Enphase disconnect tool Other Items Outdoor rated weather proof AC junction box es Gland or strain relief fitting one per ...

Страница 4: ...tall the microinverter as shown with the contoured side up Failure to do so could allow the microinverter to come in contact with the PV module back sheet Dress the Cable a Use cable clips or tie wraps to attach the cable to the racking b Dress any excess cabling in loops so that it does not contact the roof Do not form loops smaller than 4 75 inches 12 cm in diameter Keep the drop connector relea...

Страница 5: ...and connect the microinverter Listen for two clicks as the connectors engage b Cover any unused connectors with Enphase Sealing Caps Listen for two clicks as the connec tors engage See notes in Step Details c Attach the terminated cable end to the PV racking with a cable clip or tie wrap WARNING Install sealing caps on all unused AC connectors as these become live when the system is energized by t...

Страница 6: ...s LED Connect the PV Modules a Mount the PV modules above the microinverters b Connect the DC leads of each PV module to the DC input connectors of the corresponding micro inverter c Check the LED on the side of the microinverter The LED flashes six times at start up All green flashes indicate normal start up This table lists microinverter LED status for normal operation after startup LED Indicate...

Страница 7: ...C SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING Allow a minimum of 1 9 cm 0 75 between the roof and the microinverter Also allow 1 3 cm 0 50 between the back of the PV module and the top of the microinverter NOTE Torque the microinverter fasteners to the values shown Do not over torque 1 4 mounting hardware 5 N m 45 50 in lbs 5 16 mounting h...

Страница 8: ... to Enphase Click Add a New System at https enlighten enphaseenergy com Use this map to build the virtual array in Enlighten s Array Builder DOCUMENT NUMBER ENPHASEENERGY COM INSTALLATION MAP REVISION 140 00003 04 A B C D E F G H J K L M 1 2 3 4 5 6 7 To Sheet ________ To Sheet ________ To Sheet ________ To Sheet ________ Envoy Serial Label ...

Отзывы: