Encharge 3T — single-width bracket
A ) Place the wall-mount bracket on the wall so that the mounting holes
of the bracket align with the center of the stud.
*
WARNING!
Risk of injury and equipment damage. Use the unit
mounting holes only to mount the base unit of Encharge to the wall
mount. Do not use the unit mounting holes to secure the bracket to
the wall.
B ) Use a level to keep the bottom of the wall-mount bracket level.
C ) Use #20(5/16”) screws (or masonry attachments for masonry)
to attach the bracket using one screw and washer for each slot
(9.2mm/0.36”). Use minimum of three screws in each mounting
bracket. Tighten all screws to manufacturer’s specified torque
values.
D ) Verify that the wall-mount bracket is solidly attached to the wall.
*
WARNING!
Risk of injury and equipment damage. Do not mount
an Encharge 3T on a bracket that is not properly mounted.
E ) If installing additional batteries, install adjacent wall-mount brackets,
as needed. Be sure to align the mounting holes in the wall-mount
bracket to the center of the wall stud. You may install another row
of brackets above the one already installed. Maintain at least 15 cm
(six inches) vertical clearance between rows and 2.54 cm (1 inch)
horizontal clearance between units of Encharge 3T installations, and
ensure that the wall can support the structural load (weight) of the
installation.
*
WARNING!
Risk of injury and equipment damage. Do not install
4
Encharge 10T — triple-width bracket
A ) Place the wall-mount bracket on the wall so that the mounting holes of
the bracket align with the center of the stud, and the mounting holes on
the left and right align with the adjacent studs.
*
WARNING!
Risk of injury and equipment damage. Use the unit mounting
holes only to mount the base unit of Encharge to the wall mount. Do not
use the unit mounting holes to secure the bracket to the wall.
B ) Use a level to keep the bottom of the wall-mount bracket level.
C ) Use #20(5/16”) screws (or masonry attachments for masonry) to attach
the bracket using one screw and washer for each slot (9.2mm/0.36”).
Use with a minimum of nine screws in each mounting bracket to
support the three Encharge battery units. There is an array of slots so
that you can choose those that allow you to mount the bracket on studs.
Tighten all screws to manufacturer’s specified torque values.
D ) Verify that the wall-mount bracket is solidly attached to the wall.
*
WARNING!
Risk of injury and equipment damage. Do not mount
Encharge 10T batteries on a bracket that is not properly mounted.
E ) If installing additional batteries, install adjacent wall-mount brackets, as
needed. Be sure to align the mounting holes in the wall-mount bracket
to the center of the wall stud. You may install another row of brackets
above the one already installed. Maintain at least 91 cm (thirty-six
inches) vertical clearance between rows and 91 cm (thirty-six inches)
horizontal clearance between units of Encharge 10T installations or
between Encharge 10T and Encharge 3/10/3T installations, and ensure
that the wall can support the structural load (weight) of the installation.
*
WARNING!
Risk of injury and equipment damage. Do not install
more than one Encharge 10T unit per 20A branch circuit.
Allowable tilt from vertical for Encharge installation:
Single-width mounting bracket
Front view
Angle view
Wall mount
slots
Unit
mount
key
holes
Wall
mount
slots
Unit
mount
key holes
Triple-width mounting bracket
Vertical
+5° inclination
-5° inclination
430 mm
77
5 m
m
188mm
43 mm
1270 mm
478 mm
9.2mm
478 mm
43 mm
418 mm
9.2 mm
* If the difference in flatness is more than 2mm, recommend installing a substructure like
unistrut for better alignment of the units.
Mounting Surface
Flatness (Across
the Installation
width and height)
recommended to
be within 2mm*
Encharge 10T
MOUNTING SURFACE
Encharge 3T
MOUNTING SURFACE
Mounting Surface Flatness (Across
the Installation width and height)
recommended to be within 2mm*
Install the Encharge 3T (single width) or Encharge 10T (tri-
ple width) wall mount bracket
Follow the instruction below for the bracket style (single-width or triple-width)
you are installing.
*
WARNING!
Risk of injury and equipment damage. Attach the wall
mount to the wall so that it is no more than five percent from vertical. See
the following image for reference: