The cable colors are dictated by the IEC 60445 standard.
If you are using a 3x230V setup without N cable, attach the PE
cable to the PE slot and attach one cable to the L1 slot, the other
to the N slot. This is identical to the 1 phase configuration.
3) Use the provided 2 M5x16 (Torque 1.2Nm) screws to attach the
tensile protection bridge. The cable should be attached at the
unstripped portion under the slot. The unstripped cable portion
should protrude from the bridge by 1 centimeter.
Professional edition only
: Install a SIM card in the SIM card
slot at the top right of the charger unit
.
4) Lead the ethernet cable through the 3 cable grommet in the cable
block and pinch the connector onto the cable
.
5) Connect the ethernet cable to the top ethernet slot, marked
‘ETH1’, at the right side of the charger unit.
6) Secure the ethernet cable to the charger with tie wraps, using the
two positions inside of the charger unit designated ‘cable tie’
.
22
Содержание Single Wallbox
Страница 1: ...Single Wallbox Installation manual SWB_4xx_22_T2 SWB_4xx_22_C7 SWB_4xx_22_T2S SWB_4xx_22_T2SE English ...
Страница 4: ......
Страница 30: ...NTP openssl PD Proprietary PSFv2 Zlib 30 ...