To  operate  the  pump,  after  making  the  electrical  connection,  position  the  rotation  inverter  at  position  1  in  the 
desired  flow  direction.  The  pump  will  start  running.  When  the  delivery  circuit  is  closed  (usually  with  a  tap  or 
dispensing gun), the pump will continue to run for a few moments until the set pressure is reached.

 

 
CAUTION: 

When  first  used,  open  the  valve  located  above  the  buffer  tank  to  allow  all  the  air  in  the  circuit  to 

escape and avoid foam problems

.

 When the circuit is reopened, for a few moments the liquid flows out due to the 

push of the internal pressure and then the pump is activated. 
The  two  adjustment  screws  located  inside  the  pressure  switch  allow  to  establish  the  stop  and  restart  time  of  the 
pump. 

 
CAUTION: 

for models equipped with an electric variator, a connection is provided between the pressure switch 

and  the  control  panel.  The  power  supply  on  these  models  is  always  supplied  to  the  general  panel  and  not  to the 
pressure switch. On the general panel there is an AUTOMATIC / MANUAL selector to select operation with the 
pressure switch or in manual mode.

 

 

 
 
 
MAKE THE ADJUSTMENTS IN THE FOLLOWING ORDER: 
 

1)

 

INSERTION: 

To increase the insertion point when the pressure decreases, screw the calibration nut

 

     (1)

 

2)

 

DISINSERTION: 

To  increase  the  operating  point  when  the  pressure  increases,  screw  the  differential 

adjustment nut (2)

 

 
 
CONTROL PANEL WITH FLOW SWITCH: ("Dry Stop") 
 

This  is  an  accessory  available  on  all  three-phase  models  (except  EURO  20)  and  on  all  versions  with  electronic 
variator (both single-phase and three-phase). The pump is supplied with a special stainless steel fitting on which 
the flow sensor is installed. The fitting must be installed on the delivery pipe of the product, making sure that the 
turn signal on the sensor corresponds to the direction of the product. In the absence of liquid, the sensor stops the 
pump. To activate the pump on the control panel, in addition to a manual / automatic selector, there is a BY PASS 
button. In case of automatic operation, it must be pressed to allow the pump to start and fill the pipes, temporarily 
interrupting  the  flow  switch  sensor  control.  Once  the  pipes  are  filled,  the button  must  be  released  and  the  pump 
will continue to work, stopping in the absence of the liquid. 

 
 
 

Содержание EURO 20

Страница 1: ...ons for use and technical manual Self priming electric pumps EURO Enoitalia S r l Via Provinciale Pisana 162 Fraz Pieve a Ripoli 50050 Cerreto Guidi FI Tel 0571 588031 Fax 0571 588080 www enoitalia net e mail info enoitalia net ...

Страница 2: ...NS FOR STARTER This manual contains useful information for the use and management of your pumps Read the instructions carefully and follow the instructions provided before starting the pump It is very important to keep these instructions in a specially dedicated place SECURITY Danger signals General danger for people Danger of injury caused by moving parts Electric danger Danger of corrosive subst...

Страница 3: ...ons of enactment Directive 2006 95 EC low voltage directive and national dispositions of enactment Directive 2004 108 EC electromagnetic compatibility directive and national dispositions of enactment The machine also complies with the Harmonised Standards UNI EN 349 954 1 1050 547 1 2 3 894 1 2 3 953 981 1005 1 2 3 4 5 1037 UNI EN ISO 3744 7000 12100 1 2 11202 11205 11688 1 2 14121 1 13857 UNI EN ...

Страница 4: ...TYPE OF PUMP BELTED WITH TROLLEY COAXIAL MECHANICAL VARIATOR ELECTRONIC VARIATOR ...

Страница 5: ...to close the outlet pipe and let the product recycle for a few seconds avoiding overloads to the engine ATTENTION max 10 sec to avoid problems of overheating and or damage to the product The electric pump consists of the following components ENGINE TROLLEY optional in the coaxial models MOTOR PULLEY where provided PUMP PULLEY where provided BELT where provided PUMP SUPPORT RUBBER IMPELLER MECHANIC...

Страница 6: ... engine STARTING the starting mode varies according to the model purchased SINGLE PHASE COAXIAL MODELS On this type of pump the electrical panel is equipped with a double condenser one for commissioning standard on all single phase motors and a special boost condenser to guarantee additional power during start up In addition to the 0 stop position the rotation inverter also presents position 1 clo...

Страница 7: ...On these models it is possible to stop the machine either by positioning the inverter on 0 or by pressing the emergency stop button CAUTION after pressing the emergency stop to reactivate the pump turn the button in the direction of the turn signal and activate the magnetothermic switch again DOUBLE SPEED MODELS WITH BELT TRANSMISSION On these models a separate control panel is installed complete ...

Страница 8: ...TH AUTOMATIC PRESSURE SWITCH Available on all three phase models except for the EURO 20 pump and on models with electronic variator both three phase and single phase The pump is equipped with a special fitting consisting of a non return valve buffer tank in some cases it is not supplied and a pressure switch panel This fitting is installed on the pump in the liquid delivery direction check the dir...

Страница 9: ...to select operation with the pressure switch or in manual mode MAKE THE ADJUSTMENTS IN THE FOLLOWING ORDER 1 INSERTION To increase the insertion point when the pressure decreases screw the calibration nut 1 2 DISINSERTION To increase the operating point when the pressure increases screw the differential adjustment nut 2 CONTROL PANEL WITH FLOW SWITCH Dry Stop This is an accessory available on all ...

Страница 10: ...is possible to act on this valve in order to increase valve closed or decrease valve open the flow rate as you want IMPORTANT the by pass must be closed at the beginning of processing and for the suction of solid parts To switch off the machine simply position the engine switch on the center zero In the event of an emergency stop it is necessary to restart the machine in the reverse direction of r...

Страница 11: ... mains voltage Do not use extensions with insufficient diameter that may cause voltage drops Check the operation of the boost condensator on the single phase models with the disassembled pump body start the engine and check if the motor increases the vibration when the AVV position is switched on In the case of three phase motors with a thermomagnetic switch make sure you have pressed the black bu...

Страница 12: ...ious switch off switch on inversion functions The electric motor installed is with separate ventilation servoventilated The servoventilated motor is always powered at 220V single phase The pump has been adjusted to parameters that allow it to work in an optimal speed range from 0 to 890 rpm Inside the electrical panel the inverter display is visible on which the values of the output frequency of t...

Страница 13: ...tact the dealer or the manufacturer FLOW SWITCH this accessory must be connected to the appropriate connector on the electrical panel and with the appropriate terminals to the outlet port of the pump The function is to stop the pump in the absence of liquid It is activated by positioning the appropriate selector on FLUSSOSATO In the first use to allow the pump to fill the pipes it is possible to b...

Страница 14: ...WIRED REMOTE CONTROL MOTOR CONNECTOR GEAR SELECTOR STOP INVERSION POTENTIOMETER PANEL CLOSURE ...

Страница 15: ...tor with a screwdriver to set one of the 16 time ranges from 1s to 500h The set time increases by turning the selector clockwise and decreases by turning it counter clockwise 3 Setting of the time for all models Turn the time setting knob to reach the desired one When you want to use the instantaneous output check that the indicator is positioned under the 0 instantaneous exit zone Once power is s...

Отзывы: