3)
CONTROL PANEL WITH ON / OFF RADIO CONTROL:
This is an accessory available on all three-phase pump models (except EURO 20). On models with electronic
variator, a specific radio remote control is provided. The ON / OFF radio remote control simply allows the pump
to be switched on and off remotely, even if the direction and speed can not be changed. On the control panel there
is a selector for the operation of the machine with radio control, or with local commands. The direction of travel
and speed (on models with mechanical or double speed variator) must be set on the control panel.
In the case of a pump with an electric variator, the remote control has the function of switching on, switching off,
varying the speed, changing the direction of rotation. On the pump control panel there is a selector to control the
machine remotely or with the commands on it.
The maximum distance of use varies according to the rooms in which it is used. It is advisable to perform signal
tests before using the pump.
4)
PANEL WITH SETTING TIMER:
Available on all models with three-phase motorization.
FUNCTIONING:
After starting the engine, priming takes place after a few moments; if more than 10/13 seconds pass, turn off the
engine and disconnect the power cable, check the correct fixing, and the lack of holes in the supply pipes as they
can cause air infiltration. If the machine is provided with by-pass, it is possible to act on this valve in order to
increase (valve closed) or decrease (valve open) the flow rate as you want.
IMPORTANT: the by-pass must be closed at the beginning of processing and for the suction of solid parts.
To switch off the machine, simply position the engine switch on the "center zero".
In the event of an emergency stop, it is necessary to restart the machine in the reverse direction of rotation, and
immediately reverse the rotation, thus allowing the elimination of any bodies that prevent the rotation of the
impeller.
After the use, it is necessary to wash the machine in order to preserve its mechanical and hygienic characteristics.
It is necessary to run the machine for a few minutes with clean water, proceeding then with the complete emptying
of the liquid contained in the pipes and in the pump body. For sanitization, use warm water with clinical solutions
for washing and sanitizing, with concentrations compatible with the rubber components of the machine.
If a lasting stop of the machine is expected, it is advisable to introduce a few drops of glycerine oil into the pump,
then reactivate the pump for a few seconds.
Maintenance: all the pump components are checked and adjusted in the factory before shipping. So the machine
does not need any special maintenance, but only regular checks over time, which also increase the duration of the
machine.
IMPORTANT:
These checks must be carried out by qualified personnel and with the machine disconnected
from the power supply.
The checks to carry out are the following:
Check the impeller wear
4. CLEANING AND MAINTENANCE