3.2.3
Keypad lock
To activate the keypad lock:
–
Press and hold the
G
and
H
keys for a few seconds
–
The
a
symbol comes on and all the keys are locked except
for the
z
key
Fig. 15
–
Press and hold the
G
and
H
keys again for a few seconds
to deactivate the keypad lock. The lock symbol on the
display goes out.
3.3
Alarm codes and resetting
If the appliance detects a malfunction, an alarm code flashes
on the display, alternating with the temperature.
All alarms are of the automatic reset type, i.e. they are cancelled
as soon as the cause is eliminated.
Alarm
Description
CF
Failure to reach the temperature setpoint after 6 hours
(Cooling Fail)
PF
Probe damaged or disconnected (Probe Fail)
3.4
Interior equipment
i.Am
refrigerated display cabinets are supplied with the
interior equipment specified by the customer at the time of
order.
An LED lighting system illuminates the refrigerated cabinet to
ensure an optimal view of the products on display.
In the event of a malfunction or failure of the lighting system,
contact the dealer who sold the appliance.
3.4.1
Removing and fitting shelves and drawers
If necessary, shelves or drawers can be repositioned or added
inside the cabinet.
Proceed as follows to remove the shelves:
–
Unscrew the four screws (1) securing the shelf to the sides
of the cabinet
–
Remove the shelf (2).
Proceed as follows to remove a drawer:
–
Pull out the drawer (3)
–
Unscrew the screws (4) holding the drawer runners in place
–
Remove the runners (5).
2
1
2
4
5
3
Fig. 16
To reposition a shelf or drawer, simply reverse the procedures
given above.
3.4.2
Temperature distribution
Temperature distribution inside the refrigerated cabinet may
be of two types, depending on the model purchased. There
are two functioning modes:
–
static
–
ventilated.
In ventilated mode, temperature is distributed uniformly
throughout the cabinet. In static mode, natural temperature
stratification occurs: the bottom section of the cabinet is
coldest, the top warmest.
STATIC
VENTILATED
t °C
°C
°C
Fig. 17
17