5. Attach the jumper wires to the wires that you removed from
the old thermostat.
6. Slide the new imperial brass fitting from your kit onto the
new thermostat.
7. Insert the new thermostat/brass fitting combination into the
well and tighten down the brass fitting by hand.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 06-26-2006 Revised: N/A
SECTION 5: SERVICE PROCEDURES
RINSE REGULATINGTHERMOSTAT REPLACEMENT INSTRUCTIONS (CONTINUED)
29
Removing the imperial brass fitting.
Attaching the jumper wires.
Sliding imperial fitting onto new thermostat.
Putting the new thermostat in the well.
Pulling the thermostat probe and fitting from the well.
Removing the wires from the thermostat.