UPHOLSTERY CARE

 

S P E C I A L   A L E R T :

 Follow guidelines for cleaning procedures set forth 

by  the  CDC  (reference:  Isolation  Precautions),  OSHA  (reference:  Bloodborne 
Pathogen Standards), APIC (Association for Practitioners in Infection Control) 
and other appropriate federal or state agencies. 
 

Upholstery  surface  should  be  cleaned  after  each  patient.  Vinyl  upholstery  requires 
general periodic cleaning to maintain a neat appearance and prevent build-up of dirt 
and  contaminants.  A  cloth  damp  with  warm  soapy  water  followed  by  a  clear  cold 
water rinse* may be used for general cleaning of upholstery.   

Indiscriminate use of 

strong  solvents,  bleaches,  cleaners  formulated  for  nonporous  surfaces  and 
cleaners  containing  alcohol  will  severely  damage  or  discolor  vinyl  surface.

  

Procedures for removing substances that cause staining are listed below.  
 

SUBSTANCE 

SOLUTION 

PROCEDURE 

     
 

 Blood

 

Cold water- DO NOT USE 

hot or soapy water, this will 

set stain.  

THEN USE  

3/4 cup bleach  to one gallon 

warm water  for final cleaning 

IMMEDIATELY, 

following appropriate guidelines,

 

remove substance from surface.    If stain remains, 

use household ammonia directly on stain followed 

by a clear cold water rinse*.  

THEN 

Wipe entire surface with cloth damp with bleach 

solution followed by a clear cold water rinse*.  

 
     
 

Vomitus

 

Commercial Disinfectant  

THEN USE  

3/4 cup bleach  to one gallon 

warm water  for final cleaning 

IMMEDIATELY, 

following appropriate guidelines,

 

remove substance from surface. Follow with a clear 

cold water rinse*.  

THEN  

Wipe entire surface with cloth damp with bleach 

solution, followed by a clear cold water rinse*.  

        
     
 

Urine

 

1 part household ammonia to  

5 parts water 

THEN USE  

3/4 cup bleach  to one gallon 

warm water  for final cleaning 

IMMEDIATELY, 

following appropriate guidelines,

 

remove substance from surface.  Follow with a 

clear cold water rinse*. 

 THEN  

Wipe entire surface with cloth damp with bleach 

solution followed by a clear cold water rinse*.  

   

Surface   

      Mildew

 

1 Tablespoon bleach to one 

quart water 

Sponge area with solution until mildew is removed. 

Follow with a clear cold water rinse*.  

 
 

Ball-point Ink

 

 

Isopropyl alcohol 70%  

followed immediately by   

several clear water rinses 

IMMEDIATELY 

  remove mark using full strength 

Isopropyl alcohol 70%.  Rub lightly until ink is 
removed.  Wipe down several times with a clear 
cold water rinse*. Ink 

will stain

 vinyl permanently if 

not removed immediately. 

      

Chewing  

         Gum,  
     Lip Stick,  
     Grease, Oil,  
     Shoe Polish  
     Scuffs 

 

 
 

Mineral Spirits or Carbon 

Tetrachloride  

Gum:

 Following appropriate guidelines,

 

peel off 

loose gum.  Using a soft cloth damp with solution, 
rub soiled area lightly until gum is removed.  Follow 
with clear cold water rinse*. 

Lip stick, grease, oil:

 Taking care not to smear 

substance, gently remove substance with a soft 
cloth damp with solution.  Follow with clear cold 
water rinse*. 

Shoe polish:

  IMMEDIATELY remove polish as it 

contains dye which permanently stain upholstery.  
Follow with clear cold water rinse*. 

*clear cold water rinse: immerse cloth in clear cold water then wring out excess water before use.

 

 

For substances not listed call ENOCHS 1-800-428-2305 for instructions.  

The following cleaners are 

NOT RECOMMENDED

 for this product:  

powder abrasives 

steel wool 

industrial strength cleaners 

lacquer solvents 

peroxide 

full strength chlorine bleach 

waxes 

alcohol based cleaners 

vinyl cleaners & conditioners 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Front Panel 

Mains Power 

Indicator 

Model Name 

 

Mains Power 

Input Module

 

ON/OFF Switch 

& Circuit 

Breaker Reset

 

 

Power 

Supply Cord 

Input 

18 

Hand Controls

 

 

(applicable only on 4550 & 4520 

with this option)

 

Electrical  

Accessory 

Receptacles  

Back Panel 

Serial Number  

Hand Control Input 

 (on all models                

except 4510)

 

 

Instrument Warmer ON/OFF  

(applicable on 4550 & 4520 with 

this option)

 

Programmable 

Non-programmable 

 

Receptacle 

Circuit

 Breaker 

  

 

Back: Up/ Down 

Adjustment  

Height: Up/ 

Down 

Adjustment 

 

Programming 

Buttons  

Содержание Power 4510

Страница 1: ...nance 17 contact information 3 log 22 semi annual checklist 19 questions 3 Malfunction of table 5 Operational conditions 4 Paper cutter 14 Paper roll holder 14 Patient load 8 Pelvic tilt 14 adjustment 14 Power features 9 warnings 9 11 Perineal recess 14 Product at a glance 6 7 Purchase record 23 Range of motion 6 Safety information 5 Symbol definitions 4 Setting up table 8 Specifications 21 Stirru...

Страница 2: ...Vacuum Formed Top 16 Table Maintenance and Cleaning Recommendations 17 Upholstery Care 18 Preventative Maintenance Checklist 19 Troubleshooting 20 Product Specifications 21 Table Maintenance History 22 Guarantee of Quality Warranty Index 23 INDEX 24 ENOCHS Guarantee of Quality ENOCHS Inc guarantees ENOCHS products to be free from defects in material or workmanship under normal installation use and...

Страница 3: ... professionals Tables are designed to position and support patients during procedures DISPOSAL OF EQUIPMENT At the end of the product life consult local codes and ordinances for proper disposal of table accessories and other consumable goods Note products may have become contaminated from normal use MAINTENANCE AND SERVICE QUESTIONS Contact ENOCHS with questions concerning this manual proper opera...

Страница 4: ...ual electrical receptacles with circuit breaker and reset option for 4550 and 4520 only Instrument warmer located in foot end drawer option for 4550 and 4520 only Instrument warmer ON OFF switch located on front side of table illuminates when warming unit is ON Switch has internal circuit breaker with reset Irrigation basin 2 5 deep stainless steel basin Mains power entry module IEC connection int...

Страница 5: ...f tripped reset and test table functions no additional action required If table does not function call for service The Encore Power Series Tables are designed for intermittent operation with a duty cycle of 1 minute ON 9 minutes OFF DO NOT EXCEED duty cycle doing so could damage system WARNING To avoid a fire hazard or risk of electric shock this table must only be connected to a supply mains with...

Страница 6: ...h this option all foot control pedals move freely returning to neutral position without sticking applicable on all tables with this option foot control power cord free of damage and firmly held in place by strain relief at back of foot control and at table base TABLE UP DN functions exhibit smooth range of movement BACK UP DN functions exhibit smooth range of movement pelvic tilt adjusts smoothly ...

Страница 7: ...ld water rinse THEN Wipe entire surface with cloth damp with bleach solution followed by a clear cold water rinse Surface Mildew 1 Tablespoon bleach to one quart water Sponge area with solution until mildew is removed Follow with a clear cold water rinse Ball point Ink Isopropyl alcohol 70 followed immediately by several clear water rinses IMMEDIATELY remove mark using full strength Isopropyl alco...

Страница 8: ...emi annual Maintenance Inspection Checklist page 19 CLEANING RECOMMENDATIONS S PE CIAL CL EA NI NG A LE RT Follow guidelines for cleaning procedures set forth by the CDC reference Isolation Precautions OSHA reference Bloodborne Pathogen Standards APIC Association for Practitioners in Infection Control and any other appropriate federal or state agencies PAINTED OR STAINLESS STEEL SURFACES NEVER USE...

Страница 9: ...through opening and secure laminate to table 4 Insert drawer into table VACUUM FORMED TOP Top is 100 seamless and manufactured without crevices or decorative embossing that collect dirt and makes cleaning difficult Top is padded with high density foam with additional contoured padding on the sides for patient comfort Top is constructed with a steel frame and backing designed for strength and durab...

Страница 10: ... desired length To Store Push unit gently back under seat section of table Irrigation Basin Access push extension into stored position lifting slightly while pushing under seat section for direct access to basin STIRRUPS Concealed when not in use the multi position stirrups offer length as well as lateral adjustment to accommodate each patient Stirrup locks into position with weight of patient s f...

Страница 11: ...4550 s Programmable Hand Control has three memory positions along with independent controls to adjust table s HEIGHT from 18 5 to 38 and the couch BACK to various degrees from horizontal to an 80º chair position To install Connect hand control cable to input port on the back face plate of table and secure with fasteners DO NOT CONNECT ANY OTHER HAND CONTROL INTO TABLE S INPUT PORT To disconnect Un...

Страница 12: ...ns power connection at the base of the table provides power for table height and back adjustment on all models It also provides power to the dual electrical receptacles and instrument warmer available on the 4550 4520 The module consists of an ON OFF toggle switch internal circuit breaker and IEC input Connect Mains Power Plug the power cord s IEC end into the Mains Power Entry Module then plug co...

Отзывы: