Back adjustment, 10 
Before operating table, 8 
Cautions 

foot control, 5, 17 
irrigation basin, 13 
patient load, 5,8 
pull out leg extension, 15 
receptacle load, 12 
symbol, 4 

Cleaning 

foot & hand controls, 17 
not recommended, 18 
painted surfaces, 17 
stainless steel surfaces, 17 
vacuum formed top, 17, 18 

Circuit breaker 

receptacles, 12 

reset, 12 

mains power entry module, 14 

reset, 14 

Disposal of table, 3 

Duty cycle, 4,5,9 

Electrical 

cut or damaged cord, 5 
accessory receptacles, 12 

circuit breaker, 12 
 reset, 12 
maximum amp load, 12 

requirements, 4 

Electro Magnetic Interference, 8 
Extension cord use, 5 
Foot control  

cautions, 5,17  
cleaning, 17 
features, 9-10 

placement note, 9 
operation, 9-10 

warnings, 9 

Height adjustment, 9 
Hand controls 

Standard control operation, 10 
Programmable control, 11 

Introduction, 3 
Intended use of table, 3 
Instrument warming drawer, 13 
Irrigation basin  

adjustment, 13 
features, 13 

Lifting table, 8 
Leg extension  

adjustment, 15 
features, 15 

Mains power  

circuit breaker, 14 
cord replacement, 5 
indicator ,14 

 

Mains power (continued) 

Input module, 13 
reset, 13 

Maintenance, 17   

contact information, 3 
log, 22 
semi-annual checklist, 19 
questions, 3 

Malfunction of table, 5

 

Operational conditions, 4 
Paper cutter, 14

 

Paper roll holder, 14 
Patient load, 8 
Pelvic tilt, 14  

adjustment, 14 

Power features, 9 

warnings, 9, 11 

Perineal recess, 14 
Product at a glance, 6-7 
Purchase record, 23 
Range of motion, 6 
Safety information, 5 
Symbol definitions, 4 
Setting up table, 8 
Specifications, 21 
Stirrups  

adjustment, 15 
features, 15 

Storage , 16 
Technical description  3 
Transportation/storage conditions, 4 
Troubleshooting guide, 20 
Upholstery care, 18 
UL compliance, 3 
Vacuum formed top  

    cleaning , 17, 18 
    features, 16 

Warnings 

adjusting/ positioning, 5,9,10 
cauterization type procedures, 5 
duty cycle, 5 
electrical receptacle, 12 
explosive atmosphere, 5 
foot control, 9 
hand control, 10, 11 
leg extension, 15 
moving table, 8 
oxygen enriched areas, 5 
patient load, 8 
pelvic tilt, 14 
power cord replacement, 13 
removing from skid, 8 
stirrups, 15 
symbol, 4 

Warranty, 23  

 

ENOCHS  Examining Room Furniture  Inc.,    14701 Cumberland Road, Suite 107       Noblesville, IN  46060         800-428-2305        
COPYRIGHT  2018   ENCORE Series 4550, 4520, 4510                                                                                        Issue 1  9-2018 

Encore Low Access Power Tables 

                                  

MODELS:  Power 4550   Programmable Table   
                  Power 4520   General Table      
                  Power 4510   Basic Table 

                   
                  

 

 

 

Installation and   

  Operation Manual 

 

Содержание Power 4510

Страница 1: ...nance 17 contact information 3 log 22 semi annual checklist 19 questions 3 Malfunction of table 5 Operational conditions 4 Paper cutter 14 Paper roll holder 14 Patient load 8 Pelvic tilt 14 adjustment 14 Power features 9 warnings 9 11 Perineal recess 14 Product at a glance 6 7 Purchase record 23 Range of motion 6 Safety information 5 Symbol definitions 4 Setting up table 8 Specifications 21 Stirru...

Страница 2: ...Vacuum Formed Top 16 Table Maintenance and Cleaning Recommendations 17 Upholstery Care 18 Preventative Maintenance Checklist 19 Troubleshooting 20 Product Specifications 21 Table Maintenance History 22 Guarantee of Quality Warranty Index 23 INDEX 24 ENOCHS Guarantee of Quality ENOCHS Inc guarantees ENOCHS products to be free from defects in material or workmanship under normal installation use and...

Страница 3: ... professionals Tables are designed to position and support patients during procedures DISPOSAL OF EQUIPMENT At the end of the product life consult local codes and ordinances for proper disposal of table accessories and other consumable goods Note products may have become contaminated from normal use MAINTENANCE AND SERVICE QUESTIONS Contact ENOCHS with questions concerning this manual proper opera...

Страница 4: ...ual electrical receptacles with circuit breaker and reset option for 4550 and 4520 only Instrument warmer located in foot end drawer option for 4550 and 4520 only Instrument warmer ON OFF switch located on front side of table illuminates when warming unit is ON Switch has internal circuit breaker with reset Irrigation basin 2 5 deep stainless steel basin Mains power entry module IEC connection int...

Страница 5: ...f tripped reset and test table functions no additional action required If table does not function call for service The Encore Power Series Tables are designed for intermittent operation with a duty cycle of 1 minute ON 9 minutes OFF DO NOT EXCEED duty cycle doing so could damage system WARNING To avoid a fire hazard or risk of electric shock this table must only be connected to a supply mains with...

Страница 6: ...h this option all foot control pedals move freely returning to neutral position without sticking applicable on all tables with this option foot control power cord free of damage and firmly held in place by strain relief at back of foot control and at table base TABLE UP DN functions exhibit smooth range of movement BACK UP DN functions exhibit smooth range of movement pelvic tilt adjusts smoothly ...

Страница 7: ...ld water rinse THEN Wipe entire surface with cloth damp with bleach solution followed by a clear cold water rinse Surface Mildew 1 Tablespoon bleach to one quart water Sponge area with solution until mildew is removed Follow with a clear cold water rinse Ball point Ink Isopropyl alcohol 70 followed immediately by several clear water rinses IMMEDIATELY remove mark using full strength Isopropyl alco...

Страница 8: ...emi annual Maintenance Inspection Checklist page 19 CLEANING RECOMMENDATIONS S PE CIAL CL EA NI NG A LE RT Follow guidelines for cleaning procedures set forth by the CDC reference Isolation Precautions OSHA reference Bloodborne Pathogen Standards APIC Association for Practitioners in Infection Control and any other appropriate federal or state agencies PAINTED OR STAINLESS STEEL SURFACES NEVER USE...

Страница 9: ...through opening and secure laminate to table 4 Insert drawer into table VACUUM FORMED TOP Top is 100 seamless and manufactured without crevices or decorative embossing that collect dirt and makes cleaning difficult Top is padded with high density foam with additional contoured padding on the sides for patient comfort Top is constructed with a steel frame and backing designed for strength and durab...

Страница 10: ... desired length To Store Push unit gently back under seat section of table Irrigation Basin Access push extension into stored position lifting slightly while pushing under seat section for direct access to basin STIRRUPS Concealed when not in use the multi position stirrups offer length as well as lateral adjustment to accommodate each patient Stirrup locks into position with weight of patient s f...

Страница 11: ...4550 s Programmable Hand Control has three memory positions along with independent controls to adjust table s HEIGHT from 18 5 to 38 and the couch BACK to various degrees from horizontal to an 80º chair position To install Connect hand control cable to input port on the back face plate of table and secure with fasteners DO NOT CONNECT ANY OTHER HAND CONTROL INTO TABLE S INPUT PORT To disconnect Un...

Страница 12: ...ns power connection at the base of the table provides power for table height and back adjustment on all models It also provides power to the dual electrical receptacles and instrument warmer available on the 4550 4520 The module consists of an ON OFF toggle switch internal circuit breaker and IEC input Connect Mains Power Plug the power cord s IEC end into the Mains Power Entry Module then plug co...

Отзывы: