4.5
Required tools
The following tools are required to configure PTM 535:
◼
Needle adapter
Suitable adapter to contact test points as described in the previous chapter.
EnOcean can provide a mechanical design example upon request.
◼
Debugger
/
Programmer
J-Link Plus or higher from Segger is required, see:
https://www.segger.com/products/debug-probes/j-link/models/j-link-plus/
◼
J-Link Software and Documentation Pack
https://www.segger.com/downloads/jlink/#J-LinkSoftwareAndDocumentationPack
◼
PTM 535 Configuration Suite
http://www.enocean.com/en/download/
Please check PTM 535 Config help for a detailed description of the program usage.
PTM 535 Configurator uses Segger tools to communicate with the radio chip. If a
window pops up “to unlock” the device you must select NO
(details see PTM 535
Config help). Due to radio approval requirements a wrong configuration will lead
the module to stop radio transmission.
Radio module configuration is only possible with the EnOcean PTM 535 Configu-
rator tool. Follow exactly the below written sequence to chance PTM 535 config-
uration. Due to radio approval requirements, a wrong configuration will lead the
module to stop radio transmission.
Additional care has to be taken to configure correct values for DATA and STATUS
fields. Otherwise PTM 535 might not work properly together with repeaters or
receivers.