EDK 300
Getting Started
Page 8/24
© EnOcean GmbH
2.4
Example: ‘1-Channel Dimmer’ (Mode 4)
1-channel dimmer mode to dim a electrical actuator.
Telegrams from a learned push button will change
PWM output signal.
1.
Check jumper configuration of EVA 300 accord
to the image on the right side, especially MODE4
& PWM
2.
Connect EVA 300 to delivered USB power supply
3.
Learn PTM 2x0 (switch) ID to TCM3x0:
- Press EVA300 LEARN > 0.5s
(LMI & CH2 LED will light, CH0 flash)
- Push PTM 2x0 to send learn telegram
- Wait until CH0 LED will flash
- Finish learn mode with LEARN button > 0.5s
4.
PTM 2x0:
- hold O-side long time, WM signal will drop
from high to low
- hold I-side long time, PWM signal will rise from
low to high
- press 1-side short time, TCM3x0 will switch on
with last PWM value
- press 0-side short time, TCM3x0 will switch off
Attention:
If you have changed FW: Load EnOcean TCM 300 default firmware from CD
If you have changed mode settings: Clear ID
- press CLEAR button > 2s (LEDs “LMI” will light & “CH0” blink)
- press RESET (mode selection)
TCM 300
USB power supply
LMI
CH1
CH2
optional / not equipped