background image

EDK 300 
Getting Started 

Page 16/24 

© EnOcean GmbH 

 

5.

 

Press self powered switch 
 

 
 

 
 

6.

 

Radio node (switch) will be shown in node list and can be selected 

7.

 

Now it‟s possible to set up manually the EEP* Profile in the tab 

EEP View

e.g. for the RPS telegram 

8.

 

Subsequently the node button shows the label „EEP has been selected‟ 

9.

 

The tab 

EEP View

 indicate the complete EEP profile details 

 

* EnOcean Equipment Profile 
   Details see: 
   

http://www.enocean-alliance.org/

 

 
 
 
 

Содержание EDK 300

Страница 1: ...Getting Started V1 5 ...

Страница 2: ...rve good engineering practice standards As such the goods being provided are not intended to be complete in terms of required design marketing and or manufacturing related protective considerations including product safety and environmental measures typically found in end products that incorporate such electronic components or circuit board EnOcean will not be reliable for consequences of any HW o...

Страница 3: ...dates 9 3 2 Overview 9 3 3 DolphinStudio Installation 10 3 4 Check FW Version with DolphinStudio 11 3 5 Update Module FW with DolphinStudio 12 3 6 Configure STM 300 module 13 3 7 DolphinView installation presetting 14 3 8 Example EVA 300 as Transceiver Mode 1 15 4 Self powered Applications with EVA 320 and STM 300 17 4 1 Overview 17 4 2 Default Configuration 18 4 3 Example Self powered temperature...

Страница 4: ...M 300C Content of EDK 300 Developer s Kit 1x EVA 300 evaluation board for TCM 3x0 1x EVA 320 evaluation board for STM 300 1x TCM 300 on adapter board 1x STM 300 on adapter board 1x TCM 320 2x EOP 300 programmer 1x PTM 200 with test rocker 2x USB cable 1x Package leaflet with download links to documentation and software tools Additional developer kits are available for self powered radio nodes of t...

Страница 5: ...CM 300 on Adapter Board EOP 300 Programmer EVA 300 Board TCM 3x0 Mode config TCM 3x0 Repeater config TCM 3x0 RSSI LEDs Learn button Learn Mode Indicator LMI Channel LEDs Clear button LED Power EOP VCCUSB LED Power EVA VCCIO LED Programmer PROGACTIVE Optional not equipped Power ON OFF switch ...

Страница 6: ...nnel receiver mode MODE 3 4 channel receiver mode MODE 4 Dimmer mode 2LEVEL Select one two level repeater REPEATER Selector for repeater mode Buttons Reset reset the TCM3x0 module Learn add or delete ID from list standard TCM 3x0 FW Clear clear whole ID list standard TCM 3x0 FW LEDs IO indicators PWM dimmer or RSSI signal strength Modul extension slots TCM 300 adapter board connector TCM 320 conne...

Страница 7: ... supply 3 Switch on EVA 300 board 4 Learn PTM 2x0 switch ID to TCM3x0 Press EVA 300 LEARN 0 5s LMI LED will light CH0 flash Push PTM 2x0 to send learn telegram Wait until CH0 LED will flash Finish learn mode with LEARN button 0 5s 5 Switching PTM 2x0 will toggle CH0 LED relay pin Attention If you have changed TCM firmware Load EnOcean TCM 300 default firmware from CD If you have changed mode setti...

Страница 8: ... light CH0 flash Push PTM 2x0 to send learn telegram Wait until CH0 LED will flash Finish learn mode with LEARN button 0 5s 4 PTM 2x0 hold O side long time WM signal will drop from high to low hold I side long time PWM signal will rise from low to high press 1 side short time TCM3x0 will switch on with last PWM value press 0 side short time TCM3x0 will switch off Attention If you have changed FW L...

Страница 9: ...indows application which supports the whole firmware development process chip configuration programming module updating DolphinView Visualize properites of EnOcean radio nodes Receives sends and analyses radio telegrams according to the EnOcean standard Get detailed information e g subtelegram timing and signal strength Content of telegrams can be analyzed online and logged with time stamp Support...

Страница 10: ...ions window will appear press Refresh to recognize EOP 300 programmer 5 Programmer settings firmware will be update if necessary Attention If you have installed a previous DolphinStudio version it is recommended to uninstall older version If you have already installed older FTDI USB driver it is recommended to remove previous and install latest FTDI driver by cross marking installation menu at the...

Страница 11: ...udio 1 Connect EVA 300 or EVA 320 with STM TCM 3x0 plugged via EOP 300 to PC 2 Launch DolphinStudio 3 Select EOPX Program mer tab 4 Select Chip information 5 Press Retrieve button 6 Current application type and version e g TCM 300 2 0 0 0 will be shown 3 4 5 6 ...

Страница 12: ...VA 300 or EVA 320 with STM TCM 3x0 plugged via EOP 300 to PC 2 Launch DolphinStudio 3 Select EOPX Programmer tab 4 Select Programmer 5 Select FW file via Browse button chip configuration file will be automatically recognized by ending cfg hex 6 Press Execute button to start the update process 3 4 5 6 ...

Страница 13: ...st be configured first with DolphinStudio 1 Start Dolphin Studio and select Chip configuration 2 Select the module STM 300 3 The button Read configuration shows the default EEP setting FUNC 0x3F TYPE 0x7F 4 For testing the entry has to be changed into e g FUNC 0x10 room operating panels TYPE 0x03 temperature sensor 0 40 C with set point control 5 The button Write configuration set the new profile ...

Страница 14: ...o PC via USB cable and connect programmer to EVA 300 or EVA 320 3 Select COM port for serial interface COM10 4 Select the ESP serial protocol type ESP2 standard TCM 300 320 ESP2 EPM internal use ESP3 TCM 300 320 incl gateway controller firmware 5 Connect to EVA 300 board transceiver 6 Check connection via EVA 300 transceiver example see next page EnOcean Serial Protocol Future DolphinView versions...

Страница 15: ... EVA 300 configured as transceiver Mode 1 1 Check jumper configuration and TCM 300 module according to the picture on the right side 2 Connect EVA 300 via EOP 300 to PC 3 Switch on EVA 300 board power 4 DolphinView Select COM port ESP type and Connect button TCM 300 ...

Страница 16: ...and can be selected 7 Now it s possible to set up manually the EEP Profile in the tab EEP View e g for the RPS telegram 8 Subsequently the node button shows the label EEP has been selected 9 The tab EEP View indicate the complete EEP profile details EnOcean Equipment Profile Details see http www enocean alliance org 6 7 8 9 ...

Страница 17: ...ower EOP VCCUSB LED Power EVA VCCIO LED Programmer PROGACTIVE STM 300 config LED Radio send User buttons Solar cell Multiple energy harvesters Short term cap Gold cap Lithium accu optional ACCU ACCU Attention If EVA 320 STM 300 stored for more then 2 weeks in darkness then the long term capacitor Gold cap has to be disconnected from STM 300 power storage switch to external or unplug STM 300 module...

Страница 18: ... Solar ExternalSolar External Storage Selector Optional Accu Goldcap None Connector for external power source Wake up retransmit STM 300 standard FW Wake Up 1s 10s 100s None Retransmit 7 14 70 140 None Buttons Reset Button1 Button2 WAKE1 Learn WAKE0 Occupancy Modul extension slots STM 300 on adapter board Optional Power Converter ...

Страница 19: ... side retransmit every wakeup 10s storage GCAP power source solar ADIO0 NTC temperature sensor and DVDD set 2 Switch on EVA 320 board power 3 STM 300 e g EEP profile has to be config ured according to chapter 3 6 page 13 4 STM 300 will send temperature values every 10s LED1 ADIO7 will flash shortly for every transmitted telegram Self powered Sensor EVA 320 USB Transceiver Mode1 EVA 300 PC Dolphin ...

Страница 20: ... to USB transceiver Mode1 2 Press the LRN button on the EVA 320 to teach in the STM 300 in Dolphin View automatically on the basis of LRN telegram which includes the EEP no 3 DolphinView displays all received sensor telegrams 4 Select tab EEP View Attention EVA320 needs sufficient energy e g light to transfer radio telegrams DB1 data byte 1 temperature value for details see 4BS telegram EnOcean Eq...

Страница 21: ...uration according to the image right side retransmit Every wakeup 10s storage GCAP power source solar ADIO0 temperature sensor NTC ADIO1 POTI WAKE0 occupancy button 2 Use module under office light 3 STM 300 will send poti temp values every 10s EVA 300 TCM 300 config for USB receiver 1 Setup EVA 300 as transceiver gate way and connect with DolphinView 2 Switch on EVA 300 3 Check received telegrams ...

Страница 22: ...Page 22 24 EnOcean GmbH Sensor values can be visualized by using DolphinView 1 Start DolphinView and select the tab EEP View 2 Select the node 3 Diagram will show received temperature sensor and Set Point potentiometer values ...

Страница 23: ......