7.6.4.2
Advertising Interval
EMDCB by default uses an advertising interval of 20 ms.
In order to minimize latency (especially in dual-channel and single channel transmission
modes), it is possible to reduce this interval to 10 ms using the Advertsising Interval regis-
rer shown in Figure 32 below.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ADVERTISING INTERVAL (Default: 0x00)
0b00: 20 ms Interval
0b01: 10 ms Interval
Others: Reserved
ADVERTISING INTERVAL
RFU
Figure 32
–
Advertising Interval register structure
7.6.4.3
Manufacturer ID
EMDCB by default transmits using the Manufacturer ID
0x03DA
(EnOcean GmbH).
It is possible to set a different manufacturer ID using the Manufacturer ID bit field shown in
Figure 33 below.
Bit 15
Bit 14
...
Bit 1
Bit 0
Manufacturer ID (Default: 0x03DA)
0x03DA: EnOcean GmbH
MANUFACTURER ID
Figure 33
–
Manufacturer ID register structure