LC-Series Controller: 1-4 Channel

 

ENMET 

 

Manual Revision Date – June 13, 2017

 

P a g e

 | 

8

 

Manual Part No. – 80003-050 

 

 

The LC Series Control Units are single PCB design. Each Control Unit has a power supply section and 1, 2 or 4 I/O interface 
sections. 
 
Located on the bottom edge of the main PCB is a number of screw connectors. This is used to provide connections for inputs, 
outputs and external buttons:  
 

4.1.3 Connections LC1 

LC1 

T

R

A

C

O

®

P

O

W

E

R

FG

A

C

(N

)

A

C

(L

)

In

p

u

t:

1

0

0

 –

 2

4

0

 V

A

C

4

7

-6

3

 H

z

0

.3

7

5

 A

 m

a

x

O

u

tp

u

t:

2

4

V

D

C

 /

 6

2

5

 m

A

T

M

L

 1

5

1

2

4

Display PCB Connector

E

L

N

+

24
V

0

V

15

16

17

18

- OUTPUT

+

4

-20 
mA

SOUNDER

- SOUNDER

J

1

J

2

J

3

J

4

J

5

J

6

J

7

J

8

J

9

J

1

0

J

1

1

J

1

2

J

1

3

J

1

4

D5 D4

100 - 240

VAC

D C

FLT

L1

L2

SENSOR

OPTIONS

COM

N

.C

N

.O

COM

N

.C

N

.O

COM

N

.C

N

.O

1

2

3

4

5

6

7

8

9

10

11

12

13

14

19

20

21

22

 

Channel 1 

Pins 1, 2 and 3  
AC power input  
 
Pins 4 and 5  
24VDC power input  
 
Pins 6, 7 and 8  
Common Fault relay contacts  
 
Pins 9, 10 and 11  
Common Alarm level1 relay contacts  
 
Pins 12, 13 and 14 
Common Alarm level1 relay contacts 
 
Pins 15 to 18 
I/O connection to sensors 
 
Pins 19 to 20  
4-20 mA output 

 

NOTE:

 

D5 orientation is be selected for 24Vdc supply as follows 

 
Input  Output 

 
 
 
 
 

 

D5

D5

Содержание LC-SERIES

Страница 1: ...ENMET 680 Fairfield Court Ann Arbor MI 48108 734 761 1270 Fax 734 761 3220 www enmet com LC Series Controller 1 4 Channel Operation and Maintenance Manual...

Страница 2: ...ler Module 12 5 2 Analogue Output Configuration 14 5 2 1 4 20mA Current Source 14 5 2 2 4 20mA Current Sink 15 5 2 3 1 5V Voltage Output 16 6 0 MAINTENANCE 17 7 0 TECHNICAL DATA AND SPECIFICATIONS 18...

Страница 3: ...ET and delivered to the carrier in good condition When it was picked up by the carrier at ENMET it legally became your company s property If your shipment arrives damaged Keep the items packing materi...

Страница 4: ...er most indication of Fault Condition Keypad Buttons 4 2 as indicated in figure 1 that are used during normal operation and 2 that are used during setup and programming Menu Main Select Switch Increas...

Страница 5: ...V DC supply can be used to power the control unit The location of installation should be chosen with regard to the following This equipment should not be located near to known sources of heat Operatin...

Страница 6: ...LC Series Controller 1 4 Channel ENMET Manual Revision Date June 13 2017 P a g e 5 Manual Part No 80003 050 LC 4 Control Unit Figure 2 Mounting LC Series...

Страница 7: ...ly would suffice AC Mains Connection The power supply board has three screw terminals connector assigned for the connection of an AC supply Pin 1 Earth Pin 2 Live input Pin 3 Neutral input Recommendat...

Страница 8: ...ny modifications regardless of the type and quantity of detector heads being used TRACO POWER FG AC N AC L Input 100 240 VAC 47 63 Hz 0 375 A max Output 24VDC 625 mA TML 15124 Fault relay Fuse 1 Fuse...

Страница 9: ...3 Hz 0 375 A max Output 24VDC 625 mA T ML 15124 Display PCB Connector E L N 24V 0V 15 16 17 18 OUTPUT 4 20 mA SOUNDER SOUNDER J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 D5 D4 100 240 VAC D C FLT L...

Страница 10: ...13 14 J1 J2 J3 J4 J5 J6 J7 J8 J9 FS1 FS2 SW1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Power supply sectionI O interface section Channel Note connections 12 13 may not be fitted o...

Страница 11: ...s Pin 13 Signal In 1 5 Vdc Pin 14 Signal In 4 20mA Pin 15 Voltage Out to S T Pin 16 Ground to S T Chanel 2 Pins 25 to 36 The same functions as 13 to 24 Chanel 3 Pins 37 to 48 The same functions as 13...

Страница 12: ...ment e g cranes doors etc Install all cables neatly and securely Detectors for gases that are lighter than air should be positioned at or below a high level Detectors for gases that are heavier than a...

Страница 13: ...alarm level 3 Yellow LED indication of fault condition An Audible signal is also provided by a sounder mounted within Microcontroller module This provides a local audible tone during alarm or conditi...

Страница 14: ...thers OFF J1 J2 J3 J4 J5 J6 J7 J8 J9 Connect the wires from the detector head to connector on the input module observing the following Detector Head Label 4 20mA Loop Channel 1 Pin Number Channel 2 Pi...

Страница 15: ...librated if in use refer to MCU Software Configuration and System Calibration Manual 5 2 1 4 20mA Current Source Chart record er 0V Alarm level1 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 Alarm le...

Страница 16: ...1 26 27 28 29 30 31 32 33 34 35 36 Channel 2 38 39 40 41 42 43 44 45 46 47 48 Channel 3 50 51 52 53 54 55 56 57 58 59 60 Channel 4 16 17 18 LC 1 15 13 25 37 49 19 20 The Input Module can also sink cur...

Страница 17: ...41 42 43 44 45 46 47 48 Channel 3 50 51 52 53 54 55 56 57 58 59 60 Channel 4 16 17 18 LC 1 15 13 25 37 49 19 20 Chart recorder ve ve The LC Control Unit can provide a voltage output i e zero gas 1V f...

Страница 18: ...has occurred Clean control unit casing using a clean cloth Clean detector heads using a clean DAMP cloth NOTE Use of a dry cloth would constitute a static hazard Inspect detector heads and ensure the...

Страница 19: ...cates power ON LED Indications Option 2 Red Red Yellow Indicates alarm level 1 condition Indicates alarm level 2 condition Indicates fault condition Input Modules Number of channels 1 max Signal Input...

Страница 20: ...dicates alarm level 3 condition Indicates alarm level 2 condition Indicates alarm level 1 condition Indicates fault condition Input Modules Number of channels 2 max Signal Inputs x 2 4 20mA Current Lo...

Страница 21: ...d Red Red Yellow Indicates power ON Indicates alarm level 3 condition Indicates alarm level 2 condition Indicates alarm level 1 condition Indicates fault condition Input Modules Number of channels 4 m...

Страница 22: ...the inspection by the Seller confirms that the product is defective it will be repaired or replaced at no charge within the stated limitations and returned prepaid to any location in the United State...

Страница 23: ...the Service Request Form assists in the expedient service and return of your unit and failure to provide this information can result in processing delays ENMET charges a one hour minimum billing for...

Страница 24: ...it Appears on Card RETURN SHIPPING METHOD UPS Ground UPS 3 Day Select UPS Next Day Air UPS ND Air Saver UPS 2 Day Air UPS Account FedEx Ground FedEx Air Express Saver FedEx Air Overnight Std FedEx Air...

Отзывы: