1.0 Introduction 

The 

ENMET

 

EX-5165

 infrared sensor/transmitter (S/T) is a 3-wire, 24VDC 4-20mA S/T for the detection of Carbon Dioxide (CO2).  

The 

EX-5165

 is meant to be used in conjunction with an appropriate power supply and controller.  The 

ENMET

 

EX-5165

 

sensor/transmitter has been designed and approved to be used in a Class I, Div. 1, Groups B, C, D, classified areas.  The approval was 
issued by CSA International. 

 

N

OTE

:

 

All specifications stated in this manual may change without notice.

 

 

1.1 Unpack 

Unpack the 

EX-5165 

and examine it for shipping damage.  If such damage is observed, notify both 

ENMET

 customer service 

personnel and the commercial carrier involved immediately. 

 

Regarding Damaged Shipments 

 

N

OTE

It is your responsibility to follow these instructions.  If they are not followed, the carrier will not honor any claims for 

damage.

 

 

 

This shipment was carefully inspected, verified and properly packaged at 

ENMET

 and delivered to the carrier in good 

condition. 

 

When it was picked up by the carrier at 

ENMET

, it legally became your company’s property. 

 

If your shipment arrives damaged: 

o

 

Keep the items, packing material, and carton “As Is.”  Within 5 days of receipt, notify the carrier’s local office and request 
immediate inspection of the carton and the contents. 

o

 

After the inspection and after you have received written acknowledgment of the damage from the carrier, contact 

ENMET

 

Customer Service for return authorization and further instructions.  Please have your Purchase Order and Sales Order 
numbers available. 

 

ENMET

 either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually 

$100.00.  Repair or replacement charges above that value are your company’s responsibility. 

 

The shipping company may offer optional insurance coverage. 

ENMET

 only insures shipments with the shipping company 

when asked to do so in writing by our customer.  If you need your shipments insured, please forward a written request to 

ENMET

 Customer Service. 

 

Regarding Shortages 

If there are any shortages or questions regarding this shipment, please notify 

ENMET

 Customer Service within 5 days of receipt at 

the following address: 

ENMET 

680 Fairfield Court 

Ann Arbor, MI 48108 

734-761-1270 Fax 734-761-3220 

Toll Free: 800-521-2978 

1.2 Check Order 

Check, the contents of the shipment against the purchase order.  Verify that the 

EX-5165 

is received as ordered.  [Each 

EX-5165 

is 

labeled with its target gas.]  If there are accessories on the order, ascertain that they are present.  Check the contents of calibration 
kits.  Notify 

ENMET

 customer service personnel of any discrepancy immediately. 

 

1.3 Serial Numbers  

Each 

is serialized.  These numbers are on tags on the equipment and are on record in an 

ENMET

 database. 

 

 

 

Содержание EX-5165

Страница 1: ...ENMET 680 Fairfield Court Ann Arbor MI 48108 734 761 1270 Fax 734 761 3220 www enmet com EX 5165 Sensor Transmitter Operation and Maintenance Manual...

Страница 2: ...ENT PART NUMBERS 14 7 0 TERMS AND CONDITIONS 15 7 1 Ordering Information 15 7 2 Delivery 15 7 3 Payment Terms 15 7 4 Warranty Information and Guidelines 15 7 5 Return Policy 15 8 0 INSTRUCTIONS FOR RE...

Страница 3: ...on of the carton and the contents o After the inspection and after you have received written acknowledgment of the damage from the carrier contact ENMET Customer Service for return authorization and f...

Страница 4: ...c switches control the instrument maintenance functions The switch locations are indicated by MENU and SELECT A magnetic field pulse is applied by momentarily putting the end of the magnet in proximit...

Страница 5: ...fined and locations where the gas may damage or injure property or personnel when choosing locations of sensor transmitters Also take into consideration environmental factors when deciding on S T loca...

Страница 6: ...not damage the magnetic switches Remove the two overlay standoffs and remove the circuit board exposing the terminal strips on the bottom of the circuit board Do not disconnect the circuit board wirin...

Страница 7: ...age the magnetic switches Put the cover back on the S T Do Not apply power to the S T without the cover in place Printed Circuit Board PCB Display Overlay Magnetic Switches 2 places Sensor Transmitter...

Страница 8: ...Depending on transmitter configuration and calibration condition the furthest right character in the display may flash a letter indicating the instrument status Consult ENMET Distributor or ENMET for...

Страница 9: ...t over the MENU button Display indicates Alarm 1 Set point Tap the magnet over the MENU button Display indicates Alarm 2 Set point Tap the magnet over the MENU button No Function for the SELECT button...

Страница 10: ...splay Function Normal Display Mode Measurement of target gas Hold the magnet over MENU switch for 2 5 seconds to enter the Maintenance Menu The Power Fault LED will flash Green Red to indicate the EX...

Страница 11: ...ylinder of 20 9 Oxygen is used to provide a fresh air reference or Zero point for the calibration Another cylinder is used to provide the Span reference point for calibration Depending on the instrume...

Страница 12: ...gas Tap the MENU switch until Exit appears then tap the SELECT switch Check span gas and repeat calibration NOTE Some software revisions require the SELECT switch be tapped to accept the signal 7 Cali...

Страница 13: ...LECT switch to display the set point The MENU switch changes digit indicated by underscore cursor The SELECT switch locks underscored digit and moves to next digit To return to Normal Gas Display Tap...

Страница 14: ...ed from each other Plug in new Sensor PC Board Assembly Reassemble the sensor housing After the new sensor has been installed it is suggested to allow the sensor to stabilize for several minutes A Fac...

Страница 15: ...033 Sensor Infrared Carbon Dioxide for 0 5 03053 039 Sensor Infrared Carbon Dioxide for 0 20 03053 043 Sensor Infrared Carbon Dioxide for 0 60 03053 051 Consult ENMET Distributor or ENMET for addition...

Страница 16: ...on by the Seller confirms that the product is defective it will be repaired or replaced at no charge within the stated limitations and returned prepaid to any location in the United States The Seller...

Страница 17: ...Request Form assists in the expedient service and return of your unit and failure to provide this information can result in processing delays ENMET charges a one hour minimum billing for all approved...

Страница 18: ...it Appears on Card RETURN SHIPPING METHOD UPS Ground UPS 3 Day Select UPS Next Day Air UPS ND Air Saver UPS 2 Day Air UPS Account FedEx Ground FedEx Air Express Saver FedEx Air Overnight Std FedEx Air...

Отзывы: