background image

INSTALLATION & OPERATION MANUAL  

 

MODEL NUMBERS:    10-CDV      49-TRC22      49-SHC22 

 

Thank you for purchasing this product from a fine line of heating equipment.  

We wish you many years of safe heating pleasure with your new heating appliance. 

 

Save These Instructions. 

 

IMPORTANT:  IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO 

THE DEALER. CONTACT CUSTOMER SERVICE @ 1-800-245-6489. 

 
 
 

 
 
 
 
 

 

 

Mobile Home Use: 

These freestanding corn/pellet units are approved for mobile home or doublewide installation 

with outside combustion air hook-up.  See  “Flue System” section of manual. 

Mobile home installation should be in accordance with the Manufactured Home and Safety 

Standard (HUD), CFR 3280, Part 24. 

WARNING:  Do Not Install in Sleeping Room 

CAUTION: 

 

The structural integrity of the mobile home floor, wall and ceiling/roof  

must be maintained.   

 

Please Note the Following Precautionary Statements: 

 

NOTE:  WE DO NOT RECOMMEND CORN/PELLET STOVES AS YOUR ONLY SOURCE OF HEAT. 

     
 
 

 

 

CAUTION:  Please read this entire manual before installation and use of this 

corn/pellet/ fuel burning room heater.   
Keep children, furniture, fixtures and all combustibles away from 
any heating appliance. 

 

WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT

 

DO NOT OPERATE UNIT WITH HOPPER OPEN.  LID MUST BE SHUT AND TIGHTLY SECURED.

 

DO NOT OPERATE WITH DOOR OPEN

 

 

SAFETY NOTICE 

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, 
BODILY INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL THE 
INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS FOR 
RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS (INCLUDING PERMITS) IN 
YOUR AREA. 

 

Questions?  Need Parts or Options?  

www.englanderstoves.com

 

 

Rev. 1/07 

England’s Stove Works highly recommends the use of smoke detectors and 

Carbon Monoxide detectors with any hearth product, including this unit.  Follow all 

manufacturer’s instructions when using smoke or Carbon Monoxide detectors. 

 

 
 
 

Содержание 10-CDV

Страница 1: ...tements NOTE WE DO NOT RECOMMEND CORN PELLET STOVES AS YOUR ONLY SOURCE OF HEAT CAUTION Please read this entire manual before installation and use of this corn pellet fuel burning room heater Keep chi...

Страница 2: ...ing guide on our web site we have always tried to help our customers stay heat ready especially while oil and electricity prices continue to skyrocket Please look at our vast Help section on our web s...

Страница 3: ...r Also if you do not use U L approved twist lock corn pipe be sure to use U L approved Corn Vent pipe and fasten each joint of the pipe with at least three screws 7 Outside combustion air is mandatory...

Страница 4: ...er Service at 800 245 6489 if you have any questions 18 Be sure to follow the directions of all manufacturers of third party products that you use including exhaust pipe etc Never apply firestarter pr...

Страница 5: ...s contact local building or fire officials about restrictions and installation requirements in your area Read the Operations and Fuel section of this manual before plugging in your unit Always unplug...

Страница 6: ...product Important Your home must be checked to verify that there is no negative pressure that will affect the operation of this appliance IMPORTANT DO NOT BURN TREATED SEED CORN IN YOUR STOVE Seed cor...

Страница 7: ...three inch or four inch 3 or 4 type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the unit Use a three inch to four inch 3 to 4...

Страница 8: ...low and performance of the unit Each elbow or tee reduces draft potential by up to 30 Total length of horizontal vent must not exceed 48 4 ft All joints in the vent system must be fastened by at least...

Страница 9: ...anty will not cover any damage caused due to foreign objects in the fuel supply Store your pellets in a dry place to prevent them from absorbing added moisture To decrease sawdust buildup the hopper w...

Страница 10: ...8 above ground level a straight section of corn pipe can be used to initially pass through the wall see Illustration 1 Your dealer or our factory should be able to provide you with a kit that will han...

Страница 11: ...h a clamp or aluminum tape The outside end of the pipe should be covered screened to prevent foreign matter from entering the system Our Outside Air Kit Part Number PU OAK can be used If the unit is l...

Страница 12: ...let Vent Exhaust Pipe FLOOR AND WALL PROTECTION Floor Protection If your floor is constructed of a non combustible material such as brick or concrete there is no need for floor protection If the floor...

Страница 13: ...he first two minutes close the door and press the ON button located on the Control Panel The Heat Range and Blower Speed will automatically be set to setting 5 to ensure that proof of fire is detected...

Страница 14: ...Heat Range window 3 Follow lighting instructions PELLET START UP PROCEDURE NOTE When burning only pellets remove stirrer from fire pot See Illustration 2 While you will not follow the instructions in...

Страница 15: ...oor or hopper lid This will allow any smoke to exit through the external air hook up instead of spilling into the home SHUT DOWN PROCEDURE WARNING NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE P...

Страница 16: ...ower outage Open the closest outside door and a window to eliminate the home s natural draft Wait for power to be restored and then press the ON button to re start the unit if necessary NOTE Remember...

Страница 17: ...n combustible surface or on the ground until completely cooled and free of hot cinders Once the ash is removed the burn pot should be given a thorough inspection Remove and clean the burn pot Check fo...

Страница 18: ...the blower from the stove The blower impeller blower tube and steel blower exhaust tube on the unit should be brushed and vacuumed When cleaning or replacing the blower a new gasket Part PU CBG should...

Страница 19: ...if this glass becomes cracked in any area the unit should be shut down and the window replaced with this high temperature ceramic glass Auger Removal and Replacement To remove the auger from the unit...

Страница 20: ...manual for instructions on other Control Board settings Illustration 4 Control Board Diagram NOTE The bottom 3 buttons are pre set at the factory and do not need adjustment Call Customer Service at 8...

Страница 21: ...ontinue to operate until the unit cools down to below 90 degrees This may take from several minutes up to an hour Automatic Shutdown If after 15 minutes the unit has not reached the preset operating t...

Страница 22: ...There are two pieces of J Channel trim in this kit that snap onto the ash apron and top lips of the stove Match the channel with the correct edge of the lip then remove the protective covering from t...

Страница 23: ...wer Left Side Cover Plate Auger Tube Assembly with Part CU ASB 2 per stove Auger Tube Gasket 4 RPM Auger Motor Convection Blower 5 8 Hopper Flange Gasket Rear Access Panel Hopper Hopper Lid Gasket Hop...

Страница 24: ...Corn Stove Exploded View Diagram Illustration 6 24...

Страница 25: ...closed position Then take the inch wrench and loosen the nut closest to the latch This nut is then adjusted closer to the lid itself to tighten the latch After adjusting this nut to the desired locati...

Страница 26: ...2 A 3 8 x 1 1 2 Carriage Bolt and matching nut is supplied with each leg Fit a leg into a slot and match the hole on the leg with the hole in the slot Attach the legs one at a time using the supplied...

Страница 27: ...ash 4 Remove baffles Clean unit 5 Low quality pellets 5 Use premium pellets 6 Blown fuse 6 AMP 1 Power surge 1 Replace fuse use surge protector 2 Exposed wire 2 Check for exposed or frayed wire and l...

Страница 28: ...plates located on the back inside wall next to the firepot clean firepot and firebox vent holes above firebrick panel Feed rate is too High for fuel reduce heat setting Inadequate combustion air avail...

Страница 29: ...f damage occurs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect...

Страница 30: ...30...

Страница 31: ...________________________ Purchase Price ______________________ Serial Number _______________________ Mfg Date ____________________________ How did you first hear about our product please check one ___...