11 Calculator 

Operation

The 

S

ENSO

S

TAR

®

2C 

calculator has a liquid crystal display with 8 digits and special characters. The values that can be shown 

are divided into three display loops.
All data is retrieved using the Engelmann pushbutton next to the display.
To scan all the information in a loop, simply press the pushbutton brie

fl

 y. To change to the next loop press the pushbutton longer. 

Keep the pushbutton pressed until you reach the desired information loop. As soon as the desired loop appears, let go of the push-
button. After one minute of non-use of the pushbutton, the display automatically returns to the main loop.

 1. Level  / Main Loop

 1)  Total heat energy   /    total cooling energy 

–standard display-

(alternating display without pressing the 

button heat/cooling meters)

2)  Segment test, all segments triggered 

simul-taneously.

3)  Total heat energy / cooling energy at last 

billing date alternating with that date. 

1)

Flow volume, tariff values, or the values of the 

individual pulse counters can be shown if this 

has been set.

4)  Total volume in m

3

5)  Current power in kW

6)  Current flow in m

3

/h

7) Current date

8)  Error message (alternating binary and 

hexadecimal display)

9)  Selectable customer-set calculator no. 

(secondary address); factory setting is the 

serial no.

10) Tariff register1: Values alternating with 

tariff register and criteria. 

2) 3)

11) Tariff register 2: Values alternating with 

tariff register and criteria. 

2) 3)

12)  Momentary reading of the pulse counter1 

alternating with the pulse value.

2) 3)

13)  Momentary reading of the pulse counter 2 

alternating with the pulse value.

2) 3)

2.  Level / Technician’s Loop

 1)  Current forward flow temperature in C

°

2)  Current return flow temperature in C°

 3)  Temperature difference in C

°

 

4)  Days since first verification of calculator

5)  Pulse value of calculator

6)  M-bus address (primary address)

7) Serial number

8)  Software / firmware version 

9)      return flow        or      forward flow

Temperature sensor type and mounting 

position 

10) Set billing date

11), 13), 15) Maximum power value 

alternating with date and time of 

occurrence.

12), 14), 16)  Maximum flow value alternating with 

date and time of occurrence.

1)  Previous billing date alternating with its values. 

     Alternatively, the total volume, tariff values, or values of 

    individual instruments connected to the optional pulse inputs

    can be displayed, if so set. 

1)

  

2-16)  15  Monthly values: Dates alternating with their values.

            Alternatively, the total volume, tariff values, or the values of

             individual pulse counters can be displayed, if so set. 

1)

3.  Level / Statistics Loop

1)

  Up to the end of the month the consumption and billing date for that month will be shown as 0.

 

2) 

Can be set using the software “Engelmann

®

 Monitor”. A dedicated meter password is necessary. Password available from manufacturer.

3)

   Note: For invoicing, the total heat energy must be used.

Содержание SensoStar 2C Ultrasonic

Страница 1: ...to qp and approx 3 bar at overload qs specifications for approx 80 C The flow sensor left the factory in conformance with all ap plicable safety regulations Calibration maintenance repairs and the exchange of parts may only be carried out by qualified technical personnel who are familiar with the dangers involved Further technical support can be provided by the manufacturer upon request Verificati...

Страница 2: ...d contact class OA as per EN1434 2 2007 passive electronic current sink open collector class OC as per EN1434 2 2007 Installation point standard in return flow optional in forward flow only for heat meter calculator must be set in factory Mounting position Heat meter any Mounting position Cooling meter see section 6 Installation for Cooling Applica tions 4 4 Small flow sensors Nominal flow q p Ins...

Страница 3: ...50 22 G 1 1 4 B 10 16 200 48 G 2 B 10 16 300 48 G 2 B For the short models with length 150 mm the temperature range for the medium lies between 20 0 C and 130 0 C 4 7 Premium Flow Sensors Please note that the normal flow sensors may not be used with salt water Upon request we can provide salt water resistant versions of the flow sensors qp m h PN bar DN a b Øc Ød Øe No of holes f g 3 5 25 25 260 5...

Страница 4: ...o C 10 DN Black housing of transducers 5 Integration in the Heating System Please inspect and check all dimensions to be sure that there is sufficient space in the intended location for installation of the flow sensor No minimum straight pipe sections are required upstream or downstream for the flow sensor If the flow sensor is being installed in the common return flow of two heat systems e g heat...

Страница 5: ...ification must always be installed in the return flow The temperature sensors are not to be installed within the influence of other sources of heat Do not kink lengthen or shorten the cables Cables that are too long should not be rolled up tightly into an air core coil The cables should either be laid out unordered or rolled up loosely into a wide coil which can be turned and tied into an 8 Mounti...

Страница 6: ...for connection to an additional system For connection of meters with open collectors atten tion must be paid to the polarity Polarity is not important for these connections so the wires can be clamped arbitrarily When the M bus network is in operation a triangle will appear in the lower right corner of the display Power supply from the M bus network is functioning Connection of M bus Connection of...

Страница 7: ... 9 Selectable customer set calculator no secondary address factory setting is the serial no 10 Tariff register1 Values alternating with tariff register and criteria 2 3 11 Tariff register 2 Values alternating with tariff register and criteria 2 3 12 Momentary reading of the pulse counter1 alternating with the pulse value 2 3 13 Momentary reading of the pulse counter 2 alternating with the pulse va...

Страница 8: ...pulse value is automatically determined by the second to last place of the volume display The pulse units are identical to the units of the volume display Example 1 Display 12345 678 m3 pulse value for volume pulse output 0 01 m3 pulse Example 2 Display 12345678 l pulse value for volume pulse output 10 l pulse Display examples Description of example in tariff register 1 either the energy or the ti...

Страница 9: ...he optical interface using the Engelmann Monitor software They can also be set using the display The primary address is the M bus address displayed in the 2nd level technician s loop in menu item 6 M bus address primary address The secondary address is the customer identification no and can be selected under menu item 9 Selectable customer set calculator no in the first level the main loop If a cu...

Страница 10: ...se inputs Data storage E2 PROM daily Maximal value storage 3 each for flow and power Billing dates annual billing date selectable from dd mm to dd mm Monthly values 24 monthly values readable Protection class housing IP65 EMC class E1 Mechanical environment class M1 Pulse input device microcontroller CMOS input class IB as per EN1434 2 2007 Dimensions length x width x height 198 mm x 123 7 mm x 45...

Страница 11: ...rement is carried out every 30 seconds for standard instruments Example sensors switched Error Error code Binary display LCD Check sum fault E2PROM fault Reset Reference sensor fault Return fl ow senso fault Sensors switched Forward fl ow sen fault Error display hexadeci mal LCD When an error occurs with the exception of the reset and sensors switched error the instrument must be exchanged and sen...

Отзывы: