background image

Engelmann Sensor GmbH,  Rudolf-Diesel-Straße 24-28 , 69168 Wiesloch-Baiertal, Germany
Phone.: +49 (0)6222-9800-217 , Fax: +49 (0)6222-9800-50, E-Mail: [email protected],  www.engelmann.de

Article-No.  1080700010 - 2011-04-01

Engelmann

T h e   h e a t   m e t e r   s p e c i a l i s t s

®

Page 6

 

Check that the connections are tight.

 

Screw the cable glands tight by hand.

 Connection for 4-wire technique

 Connection for 2-wire technique

10.2     Connection of optional interfaces

• 

The following are options that the calculator can be equip-

ped with at the factory (state when ordering) and will vary 

depending on the individual calculator.

• 

Feed the cable to be connected (cable diameter Ø 3.5 to 6.5 

mm) through an opening on the bottom edge of the calcula-

tor housing into the space containing the terminal strips. 

• 

The terminal clamps are designed to 

fi

 t strands with ends 

with a cross-section of 0.5 – 1.5 mm

2

.  

• 

Clamp on the cable according to the following illustrations 

that apply depending on the interface.

Depending on the option, 

here there are located two 

additional pulse inputs (IN) 

for further meters or two 

pulse outputs (OUT) for 

connection to an additional 

system.
For connection of meters 

with open collectors atten-

tion must be paid to the 

polarity.

Polarity is not important for 

these connections so the wires 

can be clamped arbitrarily.
When the M-bus network is in 

operation a triangle will appear 

in the lower right corner of the 

display.  
(Power supply from the M-bus 

network is functioning.) 

Connection of M-bus

Connection of pulse outputs or inputs

Connection of power pack

It is strongly recom-

mended to use only the 

Engelmann Sensor 

power pack.
It is imperative to pay 

attention to the polarity

Important note:  The fl ow sensor is not powered by the 
                            power pack!

Attention: Please check the unused cable glands to make
                  sure that the necessary blind plugs are inserted
                  and then tighten the cable glands by hand. 

• 

Check that the connections are tight.

• 

The power pack should only be connected to 230V and 

checked by authorized technical personnel. 

• 

Check on the display whether a 

triangle appears in the lower right 

corner, as shown in the illustration.

• 

Screw the cable gland tight by hand.

• 

Close the cover of the calculator housing and protect 

against unauthorized opening using the delivered 

Optional

:

For the dual-purpose heat/

cooling meter version, sepa-

rate pulse outputs for heating 

energy and cooling energy 

are available.

Содержание SensoStar 2C Ultrasonic

Страница 1: ...to qp and approx 3 bar at overload qs specifications for approx 80 C The flow sensor left the factory in conformance with all ap plicable safety regulations Calibration maintenance repairs and the exchange of parts may only be carried out by qualified technical personnel who are familiar with the dangers involved Further technical support can be provided by the manufacturer upon request Verificati...

Страница 2: ...d contact class OA as per EN1434 2 2007 passive electronic current sink open collector class OC as per EN1434 2 2007 Installation point standard in return flow optional in forward flow only for heat meter calculator must be set in factory Mounting position Heat meter any Mounting position Cooling meter see section 6 Installation for Cooling Applica tions 4 4 Small flow sensors Nominal flow q p Ins...

Страница 3: ...50 22 G 1 1 4 B 10 16 200 48 G 2 B 10 16 300 48 G 2 B For the short models with length 150 mm the temperature range for the medium lies between 20 0 C and 130 0 C 4 7 Premium Flow Sensors Please note that the normal flow sensors may not be used with salt water Upon request we can provide salt water resistant versions of the flow sensors qp m h PN bar DN a b Øc Ød Øe No of holes f g 3 5 25 25 260 5...

Страница 4: ...o C 10 DN Black housing of transducers 5 Integration in the Heating System Please inspect and check all dimensions to be sure that there is sufficient space in the intended location for installation of the flow sensor No minimum straight pipe sections are required upstream or downstream for the flow sensor If the flow sensor is being installed in the common return flow of two heat systems e g heat...

Страница 5: ...ification must always be installed in the return flow The temperature sensors are not to be installed within the influence of other sources of heat Do not kink lengthen or shorten the cables Cables that are too long should not be rolled up tightly into an air core coil The cables should either be laid out unordered or rolled up loosely into a wide coil which can be turned and tied into an 8 Mounti...

Страница 6: ...for connection to an additional system For connection of meters with open collectors atten tion must be paid to the polarity Polarity is not important for these connections so the wires can be clamped arbitrarily When the M bus network is in operation a triangle will appear in the lower right corner of the display Power supply from the M bus network is functioning Connection of M bus Connection of...

Страница 7: ... 9 Selectable customer set calculator no secondary address factory setting is the serial no 10 Tariff register1 Values alternating with tariff register and criteria 2 3 11 Tariff register 2 Values alternating with tariff register and criteria 2 3 12 Momentary reading of the pulse counter1 alternating with the pulse value 2 3 13 Momentary reading of the pulse counter 2 alternating with the pulse va...

Страница 8: ...pulse value is automatically determined by the second to last place of the volume display The pulse units are identical to the units of the volume display Example 1 Display 12345 678 m3 pulse value for volume pulse output 0 01 m3 pulse Example 2 Display 12345678 l pulse value for volume pulse output 10 l pulse Display examples Description of example in tariff register 1 either the energy or the ti...

Страница 9: ...he optical interface using the Engelmann Monitor software They can also be set using the display The primary address is the M bus address displayed in the 2nd level technician s loop in menu item 6 M bus address primary address The secondary address is the customer identification no and can be selected under menu item 9 Selectable customer set calculator no in the first level the main loop If a cu...

Страница 10: ...se inputs Data storage E2 PROM daily Maximal value storage 3 each for flow and power Billing dates annual billing date selectable from dd mm to dd mm Monthly values 24 monthly values readable Protection class housing IP65 EMC class E1 Mechanical environment class M1 Pulse input device microcontroller CMOS input class IB as per EN1434 2 2007 Dimensions length x width x height 198 mm x 123 7 mm x 45...

Страница 11: ...rement is carried out every 30 seconds for standard instruments Example sensors switched Error Error code Binary display LCD Check sum fault E2PROM fault Reset Reference sensor fault Return fl ow senso fault Sensors switched Forward fl ow sen fault Error display hexadeci mal LCD When an error occurs with the exception of the reset and sensors switched error the instrument must be exchanged and sen...

Отзывы: