 14 Technical Data

Calculator

Ambient temperature

°C

5 ... 55

Temperature range

°C

1 ... 150 °C (optional 1 ... 180 °C)

Temperature difference 
heat

K

3 K... 100 K

(3 ... 130 for temperature meas-

urement range 1 °C  - 180 °C)

Temperature difference 
cooling

K

-3 K...  -50 K

Calculation of heat from

K

∆Θ

> 0.05

Calculation of cooling from

K

∆Θ

< -0.05

Dual-purpose heat/
cooling meter

K

∆Θ

HC

< -0.5

Resolution temperature

°C

0,01

Measurement cycle

30 seconds 

(with external power supply 4 sec.)

Power supply

stan-

dard

3,6 V lithium 

(6+1 years)

optional

3V power pack

supply via M-bus

Pulse values

stan-

dard

see type identi

fi

 cation

Pulse length

min. pulse length 25 ms

min. pulse interval 25 ms

Display

LCD 8 special characters

Units

stan-

dard

MWh

optional

kWh, GJ

Interfaces

stan-

dard

infrared

optional

M-Bus

2 potential-free contact outputs for

volume and energy

 

or

2 additional pulse inputs

(max. length of cable 10 m)

2 potential-free contact outputs for

heat- and cooling energy (dual-

purpose meters)     

or

2 additional pulse inputs

Data storage

E

2

PROM / daily

Maximal value storage

3 each for 

fl

 ow and power

Billing dates

annual billing date selectable

 (from dd.mm. to dd.mm.)

Monthly values

24 monthly values readable

Protection class housing

IP65

EMC

class E1

Mechanical environment

class M1

Pulse input device

microcontroller CMOS input class IB as per 

EN1434-2:2007

Dimensions

length x width x height

198 mm    x  123.7 mm    x  45.8 mm

Weight

approx. 250 g

Requirements for the temperature sensor pair

Platinum precision resistor  Pt500; separately approved type 

as per EN 60751 

Length of connecting 
cables (unshielded)

  3 m in 2-wire technique
10 m in 4-wire technique

Installation

direct 
in temperature pocket as per 
EN1434

In the case of non-permanently attached temperature sensors 

the temperature sensors that are later connected must meet the 

following requirements:

Application

Requirements for separate tem-
perature sensors

Heat meter

EU (MID) identi

fi

 cation on the tempera-

ture sensors

Cooling meter

National approval as a temperature 

sensor for cooling meters *)

Dual-purpose heat 

and cooling meter

EU (MID) identi

fi

 cation and 

separate national approval as a 

temperature sensor for cooling meters *)

*) Requirements in countries other than Germany may be different.

All classes refer to the currently valid legal requirements for heat 
meters (see Declaration of Conformity). 

15 

Application of Confi guration Software

 Engelmann

®

 Monitor 

Available separately (including instructions).

Содержание SensoStar 2C Ultrasonic

Страница 1: ...to qp and approx 3 bar at overload qs specifications for approx 80 C The flow sensor left the factory in conformance with all ap plicable safety regulations Calibration maintenance repairs and the exchange of parts may only be carried out by qualified technical personnel who are familiar with the dangers involved Further technical support can be provided by the manufacturer upon request Verificati...

Страница 2: ...d contact class OA as per EN1434 2 2007 passive electronic current sink open collector class OC as per EN1434 2 2007 Installation point standard in return flow optional in forward flow only for heat meter calculator must be set in factory Mounting position Heat meter any Mounting position Cooling meter see section 6 Installation for Cooling Applica tions 4 4 Small flow sensors Nominal flow q p Ins...

Страница 3: ...50 22 G 1 1 4 B 10 16 200 48 G 2 B 10 16 300 48 G 2 B For the short models with length 150 mm the temperature range for the medium lies between 20 0 C and 130 0 C 4 7 Premium Flow Sensors Please note that the normal flow sensors may not be used with salt water Upon request we can provide salt water resistant versions of the flow sensors qp m h PN bar DN a b Øc Ød Øe No of holes f g 3 5 25 25 260 5...

Страница 4: ...o C 10 DN Black housing of transducers 5 Integration in the Heating System Please inspect and check all dimensions to be sure that there is sufficient space in the intended location for installation of the flow sensor No minimum straight pipe sections are required upstream or downstream for the flow sensor If the flow sensor is being installed in the common return flow of two heat systems e g heat...

Страница 5: ...ification must always be installed in the return flow The temperature sensors are not to be installed within the influence of other sources of heat Do not kink lengthen or shorten the cables Cables that are too long should not be rolled up tightly into an air core coil The cables should either be laid out unordered or rolled up loosely into a wide coil which can be turned and tied into an 8 Mounti...

Страница 6: ...for connection to an additional system For connection of meters with open collectors atten tion must be paid to the polarity Polarity is not important for these connections so the wires can be clamped arbitrarily When the M bus network is in operation a triangle will appear in the lower right corner of the display Power supply from the M bus network is functioning Connection of M bus Connection of...

Страница 7: ... 9 Selectable customer set calculator no secondary address factory setting is the serial no 10 Tariff register1 Values alternating with tariff register and criteria 2 3 11 Tariff register 2 Values alternating with tariff register and criteria 2 3 12 Momentary reading of the pulse counter1 alternating with the pulse value 2 3 13 Momentary reading of the pulse counter 2 alternating with the pulse va...

Страница 8: ...pulse value is automatically determined by the second to last place of the volume display The pulse units are identical to the units of the volume display Example 1 Display 12345 678 m3 pulse value for volume pulse output 0 01 m3 pulse Example 2 Display 12345678 l pulse value for volume pulse output 10 l pulse Display examples Description of example in tariff register 1 either the energy or the ti...

Страница 9: ...he optical interface using the Engelmann Monitor software They can also be set using the display The primary address is the M bus address displayed in the 2nd level technician s loop in menu item 6 M bus address primary address The secondary address is the customer identification no and can be selected under menu item 9 Selectable customer set calculator no in the first level the main loop If a cu...

Страница 10: ...se inputs Data storage E2 PROM daily Maximal value storage 3 each for flow and power Billing dates annual billing date selectable from dd mm to dd mm Monthly values 24 monthly values readable Protection class housing IP65 EMC class E1 Mechanical environment class M1 Pulse input device microcontroller CMOS input class IB as per EN1434 2 2007 Dimensions length x width x height 198 mm x 123 7 mm x 45...

Страница 11: ...rement is carried out every 30 seconds for standard instruments Example sensors switched Error Error code Binary display LCD Check sum fault E2PROM fault Reset Reference sensor fault Return fl ow senso fault Sensors switched Forward fl ow sen fault Error display hexadeci mal LCD When an error occurs with the exception of the reset and sensors switched error the instrument must be exchanged and sen...

Отзывы: