Page 29 of 59
Article no.: 5081200002 2022_10_17 Subject to technical change! Errors excepted.
conductor was
detected.
H 16 / Bit 4
Break of one of the
measuring sensors.
No calculations are carried out. The
register for consumption is not being
updated.
Defect on PCB board, high-
resistance NTC; defect of the
remote sensor in the remote
sensor operating mode
H 32 / Bit 5
Short circuit of one of
the measuring sensors.
No calculations are carried out. The
register for consumption is not being
updated.
Defect on PCB board, low-
resistance NTC; defect of the
remote sensor in the remote
sensor operating mode
H 64 / Bit 6
Reset by watch dog
timer.
The measured values and the time
since the last saving in the E
2
PROM
are lost (max. one hour). Calculations
are still being carried out.
Undefined program status,
program sequence is not
within the specified time
cycle.
H 128 / Bit 7 Remote sensor is
mounted.
No influence on the calculation.
Remote sensor was mounted.