7 Troubleshooting
7. Troubleshooting
7.1. Q-Safe
!
!
EC
!
7
2
1
3
4
5
6
7.1.1. Indications
Position
Behaviour
Indicates
Remarks
1
1 flash
*_*_*_
Power supply OK
Applies to DC2 without QSC
2 flashes
**_**_**_
Power supply OK
Applies to QSC
Constant light
Power supply OK
Applies to SS0-SS9 without
QSC
2
1 flash
*_*_*_
CAN time out
Applies to QSC
2 flashes
**_**_**_
Short circuit, power to sensor
in EC
Applies to SS0-SS9 without
QSC and QSC during start
3 flashes
***_***_***_
Short circuit, power to sensor
in RF
Applies to SS0-SS9 without
QSC and QSC during start
3 flashes
***_***_***_
Short circuit, power to sensor
in EC
Applies to DC2
Inactive
No fault
3
Constant light
Connected tool
Sensor, hook for quick hitch on
machine
4
Constant light
Connected tool
Sensor, ejector for quick hitch
on machine
50
Содержание EC204
Страница 65: ...11 Service Date 500 h 250 h 2000 h Remark Action Stamp Signature 65...
Страница 66: ...11 Service Date 250 h 2000 h Remark Action Stamp Signature 66...
Страница 67: ...11 Service Date 250 h 2000 h Remark Action Stamp Signature 67...