1.

 

Mount the sensor and reflector so that they face 
each other. 

2.

 

Connect power to the sensor.  The LED will light as 
indicated in the chart below. 

3.

 

Unscrew the 4 cover screws and remove the cover. 

4.

 

To find the correct alignment, slowly turn the lens 
assembly left and right to adjust the horizontal angle. 

5.

 

Loosen the vertical adjustment screw to adjust the 
vertical angle. 

6.

 

Place the hood on the sensor by sliding the hood’s 

ridges into the slots on the sides of the sensor. 

7.

 

Re-attach the cover, replace the four screws, and 
attach the hood to the top of the sensor. 

1.

 

Unscrew the four cover screws and remove the cover. 

2.

 

Loosen the captive screw and remove the sensor 
from the mounting plate. 

3.

 

Using the included mounting screws, mount the 

mounting plate to the wall. 

4.

 

Use the cable breakout and cable connector at 

the bottom or rear of the sensor to run the wires. 

5.

 

Hang the sensor back on the plate and use the captive screw to secure it in place. 

6.

 

Re-attach the cover, replace the four screws, and attach the hood to the top of the sensor. 

 

Mounting: 

Alignment: 

Solid green 

Good beam signal, 

properly aligned 

Alternating flash 

Poor beam signal 

Solid red 

No beam signal, 

triggered 

 

Lens 

alignment 

±90

 

±5

 

Horizontal 

adjustment 

Vertical 

adjustment 

Wiring for the Rear Cable Breakout 

1.

 

Puncture the cable breakout located at the rear of 
the sensor using a screwdriver or other object.   

2.

 

Run wires through the included rubber ring. 

3.

 

Install the weatherproofing ring with the wires already 

installed in the cable breakout hole. 

4.

 

Make sure the ring is secure and there is no room for 
water to get into the unit. 

Rubber 

ring 

Cable 

breakout 

Wiring for the Bottom Cable Breakout 

1.

 

Puncture the cable breakout located at the bottom of 

the sensor using a screwdriver or other object. 

2.

 

Insert the short end side of the cable connector 

into the cable breakout hole and use the nut to 
secure it, tightening with a wrench as needed. 

3.

 

Run the wires through the end cap and cable connector. 

4.

 

Then screw the end cap into the external side of the cable 
connector to prevent water from entering the unit. 
 

Cable 
Connector 

End cap 

Sensor 

Nut 

Rubber 

neck 

Содержание E-931-S50RRQ

Страница 1: ...nsation housing 12 250 VAC VDC Form C relay 1A 30VDC Beam status LED N C Tamper switch 500mA 30VDC Caution This sensor is not designed to prevent bodily injury or loss of life This sensor is not designed for use in environments where explosive gasses may be present Use of this sensor in certain security applications may be regulated by local laws or codes SECO LARM is not responsible for complianc...

Страница 2: ...Rating IP66 Operating temperature 13 140 F 25 60 C Parts List 1x Sensor 1x Reflector 1x Mounting bracket 1x Sensor hood 4x Cover screws 2x Mounting screws 1x Reflector mounting screw 1x Rubber ring 1x Cable connector 1x Manual 1x Removable terminal block Overview Tamper switch Vertical adjustment screw without cover Cover Cover screw Wire cable connector Mounting plate Hood Dimensions Beam sensor ...

Страница 3: ...ew to secure it in place 6 Re attach the cover replace the four screws and attach the hood to the top of the sensor Mounting Alignment Solid green Good beam signal properly aligned Alternating flash Poor beam signal Solid red No beam signal triggered Lens alignment 90 5 Horizontal adjustment Vertical adjustment Wiring for the Rear Cable Breakout 1 Puncture the cable breakout located at the rear of...

Страница 4: ... at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2012 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the writt...

Отзывы: