4.1 Attaching the Bracket Using Tape
Preparation
1. Clean the surface of the bracket and the mounting surface well.
A typical surface cleaning solvent is IPA/water mixture (rubbing alcohol)
2. Remove all grease, dirt and oxide particles from the bonding surface.
3. Wipe the surface dry.
4. Refer to the 3M documentation to obtain more detailed guidance:
http://training.enfora.com/docs/3MVHBTape.html
Pressure sensitive adhesives use viscous flow to achieve substrate contact area.
The ideal tape application temperature range is 70°F to 100°F (21°C to 38°C).
The minimum suggested application temperature is 50°F (10°C)
Note: Initial tape application to surfaces at temperatures below the suggested
minimum is not recommended because the adhesive becomes too firm to adhere
readily. However, once properly applied, low temperature holding is generally
satisfactory. To obtain good performance with all 3M™ VHB™ Tapes, it is important
to ensure that the surfaces are dry and free of condensed moisture.
Attachment
1. Insert the device into the bracket.
2. Apply the tape provided to the surface of the bracket, as shown.
3. Remove the tape covering and attach the bracket to the surface.
4. Apply firm pressure (Greater than 15 psi is recommended)
5. It is recommended to wait at least 20 Minutes for the adhesive to bond.
- 27 -
Содержание Spider AT 3000
Страница 1: ...AT 3000 Series User Guide GSM5218UG001 Version 1 00 01 March 2011 ...
Страница 16: ...Figure 2 Top View of Spider AT 3000 Series Figure 3 Bottom View of Spider AT 3000 Series 4 ...
Страница 19: ...Figure 4 Spider AT 3000 Dimensions 7 ...
Страница 66: ...Figure 29 Hardware Wizard Windows Logo testing Note If you see this warning click on Continue Anyway 54 ...
Страница 69: ... 57 ...