Enervent® ECC EN 2010_2
INST
ALL
ATION
EQUIPMENT
INCLUDED IN THE DELIVERY OF THE UNIT:
1.
Enervent® greenair ventilation unit
2.
Control panel *
3.
Control panel cable RJ11, length 20 m (installation in a min 16 mm conduit) *
SEPARATELY SOLD EXTRA EQUIPMENT:
1.
Control panel ECC-05(E), max. 1+4 panels can be connected to the unit.
2.
Control panel cable RJ11 (length 20 m)
3.
Push button for over-pressure control.
4.
Class F7 filters.
5.
Fine filter cassette F7 in duct casing.
* Does not concern Pingvin units. Pingvin units have a fixed control panel.
INSTALLATION
Install the Plaza, Pingvin, Pandion, Pelican and Pegasos units in a warm space (over +5°C) such as a utility room or a
laundry but not a garage (separate fire area). The unit is installed hanging on the wall (Plaza, Pingvin, Pandion) or stan-
ding on the floor (Pandion, Pelican, Pegasos).
The LTR-3, LTR-6 and LTR-7 units can be installed in either a warm or cold space. The unit must be eqipped with 100 mm
extra insulation, if t is installed in a cold space. Suitable places for installation are for instance store rooms or on the attic.
The unit should be placed on a plain surface on a elastic material that absorb sound. For example, a 100 mm thick insula-
tion plate is suitable as bedding
If the unit is used to ventilate an area with a swimming pool, the unit must be drained. There is a drain outlet in the bot-
tom of the unit (1/4” inner thread). At the time of delivery, the outlet is plugged.
PHASES OF INSTALLATION:
N.B.! To reduce the weight of the unit you can remove the heat recovery wheel before mounting the unit.
Plaza, Pingvin and Pandion on the wall
1.
Mark and cut the holes into the ceiling.
2.
Draw the ducts through the holes to the required height. The gaps between duct and steam barrier are then
sealed, with for instance ventilation tape.
3.
Pingvin and Pandion units: Install the rear attachment bracket directly to the wall at required height. An insula-
tion board can be installed behind the unit to reduce the transfer of machine noise or vibration.
Place the unit onto the lower bracket and fasten to the wall with the two top brackets. Attach the lower bracket
with plate screws to the bottom of the unit. It is vital that the Pingvin unit is a little tilted backwards to ensure
the function of the condense water drain on the unit. Should be checked with a level!
Other units: An insulation board can be installed behind the unit to reduce the transfer of machine noise or
vibration. Lift the unit onto the wall and fasten it to the wall with the two top brackets.
4.
Connect the ducts to the tubes on top of the unit. It is recommended that silencers be installed to the exhaust
air and supply air ducts.
5.
If the unit’s condensation drain is to be used, connect a pipe between the drain outlet and the nearest floor
drain or water trap of a sink. Connecting the unit directly into the sewage system is not allowed.
Pandion on the floor, Pelican and Pegasos
1.
Install the unit on the floor or on a level built for the unit so that it stands on its own rubber pads. Leave at least
a 10 mm opening between the back of the unit and the wall and a, at least, 15 mm opening to the sides. Also
take in to account the space needed for drainage below the unit.
2.
Make sure that there is at least 95 cm of free space in front of the units maintenance hatch and remember to
leave the electric wirings easily accessible. The unit has a connecting plug. The connecting cable is located in
one of the front corners above the smaller door. The length of the cable is 120 cm.
3.
Connect the ducts to the unit with flexible connectors. Silencers are recommended to the supply air and exhaust
air ducts.
4.
If the unit’s condensation drain is to be used, connect a pipe between the drain outlet and the nearest floor
drain or water trap of a sink. Connecting the unit directly into the sewage system is not allowed.