95
Operating and maintenance instructions for the ventilation unit
Enervent Pelican
PRODUCT INFORMATION ACCORDING TO
EU COMMISSION REGULATION NO 1253/2014 AND 1254/2014
A
Supplier’s name or trade mark
Enervent
Supplier’s model identifier
Pelican
Specific energy consumption (sec) in kWh/(m
2
.A)
• Cold climate
• Average climate
• Warm climate
-82,17
-39,53
-15,10
Declared typology in accordance with article 2 of this regulation
RVU / BVU
Type of drive installed or intended to be installed
Multi-speed drive
Type of heat recovery system
Regenerative
Thermal efficiency of heat recovery
78,7
Maximum flow rate in m
3
/h
533
Electric power input of the fan drive, including any motor control equip-
ment, at maximum flow rate (W)
275
Sound power level (L
WA
), rounded to the nearest integer
43
Reference flow rate in m
3
/s
0,104
Reference pressure difference in Pa
50
SPI in W/(m
3
/h)
0,38
Control factor and control typology in accordance with the relevant
definitions and classification in annex VIII, table 1
0,65
Declared maximum internal and external leakage rates (%) for bidirec-
tional ventilation units
<4% / <2%
Position and description of visual filter warning for rvus intended for use
with filters, including text pointing out the importance of regular filter
changes for performance and energy efficiency of the unit
Filter warning on control
panel. Instructions in user
manual.
Internet address for disassembly instructions as referred to in point 3
https://doc.enervent.com/out/
out.ViewFolder.php?folder-
id=957
The annual electricity consumption (AEC) (in kWh electricity/a)
203
The annual heating saved (AHS) (in kWh primary energy/a) for each type
of climate
• Cold climate
• Average climate
• Warm climate
8724
4459
2016
The information on the energy label for this product has been defined with local demand control. Local demand control means that the ventilation unit continuously regulates the fan
speed(s) and flow rates based on more than one sensor. Please remember to connect all local sensors (some sold as extra equipment) in order to achieve the declared energy class.
Содержание eWind Pelican
Страница 15: ...15 Ilmanvaihtolaitteen k ytt ja yll pito ohje 6 Suodattimien vaihto 1 Pelican eWind 2 3 4 5 M5 F OFF...
Страница 19: ...19 Ilmanvaihtolaitteen k ytt ja yll pito ohje Veden lis minen vesilukkoon kondenssiveden poisto...
Страница 24: ...24 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN A 44 dB 374 m3 h...
Страница 25: ...25 Ilmanvaihtolaitteen k ytt ja yll pito ohje...
Страница 26: ...26 Pelican eWind Drift och underh llsanvisningar f r ventilationsaggregatet Svenska...
Страница 39: ...39 Drift och underh llsanvisningar f r ventilationsaggregatet Filterbyte 6 1 Pelican eWind 2 3 4 5 M5 F OFF...
Страница 48: ...48 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN A 44 dB 374 m3 h...
Страница 49: ...49 Drift och underh llsanvisningar f r ventilationsaggregatet...
Страница 50: ...50 Pelican eWind Drift och underh llsanvisningar f r ventilationsaggregatet Norsk...
Страница 63: ...63 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten Skifte ut filter 6 1 Pelican eWind 2 3 4 5 M5 F OFF...
Страница 67: ...67 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten Tilsette vann i vannl sen tapping av kondensvann...
Страница 72: ...72 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN A 44 dB 374 m3 h...
Страница 73: ...73 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten...
Страница 74: ...74 Pelican eWind Operating and maintenance instructions for the ventilation unit English...
Страница 96: ...96 2016 1254 2014 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN A 44 dB 374 m3 h...
Страница 97: ...97 Operating and maintenance instructions for the ventilation unit...
Страница 98: ......
Страница 99: ......