16
Step 3
Step 4
Figure 8 Bracket installation
Step2:
Use the bracket to install the inverter onto the narrow vertical panel (or wall). make
upper corner part of inverter hanging onto the bracket, lower part match the standard of the
bracket.See step 2.
Step3:
Make sure the bracket and the inverter side screw holes in a line and matching
well, put the screw(there are left and right 2 screws ) into the hole and drive into the
inverter tightly. See step 3.
Step4:
Lock the inverter and the bracket with lock for safety consideration. (This is
optional for users. User can select the lock according to your requirements).See step 4.
5.5 Connections of the PV power system
●PV String input connection
SolarLake series inverters (SolarLake 10000TL, SolarLake 12000TL, SolarLake 15000TL
and SolarLake 17000TL) can be connected to 2 PV string groups, each group can divided
into 2-strings PV modules. Please select PV modules with excellent function and reliable
quality. Open-circuit voltage of module arrays connected in series should be
<
Max. Input
DC (Table 3) input voltage; operating voltage should be conformed to MPPT voltage range.
Model
Max. Input DC voltage
1000 V
Table 3 Max. DC Voltage Limitation
Installation
SolarLake
10000TL
SolarLake
12000TL
SolarLake
15000TL
SolarLake
17000TL