9
TROUBLESHOOTING
PROBLEM
CAUSE
1.
Loose connections:
a.
Check the connections on the top of the battery to
make sure they are tight.
b.
Check the headpiece terminals and the electrical
connections inside the headpiece in the same manner
as those on the battery.
LED is dim or fails to light
1)
Both LED’s are dim / fail to light
2)
Main LED is dim / fails to light
2.
Loose connections:
a.
Gently wiggle or pry each connection on top of the
battery to make sure it is tight and working properly.
b.
Check the cables for broken conductors by twisting or
pulling it at various points along its length.
c.
Check the headpiece terminals and the electrical
connections inside the headpiece in the same manner
as those on the battery.
d.
Make sure the bulb is secure and making good
contact.
e.
If the light flickers or dims when any of the preceding
items are being checked, that item should be repaired
or replaced.
Battery appears “dead” and will not operate
a.
Check that the fuse has not blown
b.
Check the cross volts of the battery, if no voltage is
recorded the Safety Circuit has activated either
because the fuse has been disconnected or blown or
the battery has been over discharged.
c.
After checking continuity across the fuse, place battery
on charge (switched off) and leave for 10 seconds.
Disconnect then reconnect, the charger should then
initialise the charge regime and the battery will
recharge normally.
Battery capacity
a.
The 16 Ah Li Ion battery is designed for 12 hour
operation. Failure to achieve this is probably due to a
high resistant joint in the circuit.
b.
Check Headpiece charging connections
c.
Check charger.
d.
Check battery connections.
IMPORTANT : ALWAYS RECHARGE THE LAMP AFTER USE.
ENSURE THAT ONLY CHARGERS WITH THE
CORRECT LI-ION CHARGE PROFILE ARE USED.