Use of equipment:-
The user must ensure that the lamp supplied meets the safety standard required for the Zoned
area:-
1. This equipment can be used in a Category M1 zone
2. Check that the operating temperature range is in the range 0
o
C to +40
o
C for Mining.
3. The lamp must not be disassembled in a hazardous area.
4. The lamp must not be charged in a hazardous area.
5. The cap light and battery casings are manufactured from polycarbonate and ABS with
nitrile rubber seals. The performance of these materials, with respect to attack by
aggressive substances that may be present in the hazardous area, shall be taken into
account before the equipment is used.
6. Plastic surfaces may cause propagating brush discharges. Propagating brush discharges
are caused by non-conducting fluid flow over a non-conducting plastic surface. The cap
lights shall not be used in areas where a high fluid flow over the plastic surfaces may occur
(for example in the case of a ruptured process pipe or compressed air pipe).
EnerSys
March 2009