2
1.1.
Microprocessor-controlled
1.2.
Able to auto identify battery’s capacity
1.3.
Able to adapt to State of Charge (SoC)
1.4.
Compatible with battery voltages of:
1ph
3ph
12V
24V
24/36/48V
36/48V
72/80V
96V
120V
1.5.
Wireless integration with EnerSys
®
Wi-iQ
®
battery monitoring devices
1.6.
Individual battery pack recognition and automatic pairing with the charger
1.7.
Unique profile for charging Thin Plate Pure Lead (TPPL)
1.8.
Unique profiles for NexSys
®
battery charge applications: NXBLOC;
NXSTND; NXSFAST; NXP2V; NXPBLC.
1.9.
Remote access via E Connect™ mobile app to change settings, monitor
charger and share data.
1.10.
Controller Area Network (CAN) communication capable.
1.11.
Fully programmable to unique fleet requirements.
1.12.
Battery chemistry agnostic - EnerSys® Lithium-ion (Li-ion), TPPL, Flooded
and Gel Lead Acid batteries.
2.1. Name plate labels
2.1.1. Name plate label definitions
1. Features
TABLE OF CONTENTS
2. Technical Information
BATTERY CHARGER
INSTRUCTIONS FOR USE
Item
Description
Serial Number
Provides date code.
Hertz
Input voltage frequency. Under no conditions operate
the charger at a different frequency or from a generator
with unstable frequency.
Phase
TCX. When “1” indicates a Single Phase Charger
and “3” indicates a Three Phase Charger.
AC Volts
Nominal voltage for which this charger is rated to operate.
DC Volts
Nominal DC output voltage of the charger
Modules
Actual number of power modules installed
in the charger cabinet.
DC Amps
DC current that this charger will deliver
to a discharged battery with the number of power modules
installed and based on the Nominal Voltage
2.1.2. Output power letter codes
Output Power
(kW)
Number
Modules
Module Power
(kW)
1.0
1
1.0
2.0
2
1.0
3.0
3
1.0
3.5
1
3.5
7.0
2
3.5
10.5
3
3.5
14.0
4
3.5
17.5
5
3.5
21.0
6
3.5
24.5
7
3.5
28.0
8
3.5
2.1.3. Cabinet size (number of modules available) and DC cable size
Phases
Module
Positions
Standard
Cable Gauge
Comments
1ph
Max 1
6 mm
2
Stand alone cabinet
1ph
Max 3
25 mm
2
Three slot, 3 kW cabinet
3ph
Max 2
35 mm
2
Two slot, 7 kW cabinet
3ph
Max 4
70 mm
2
Four slot, 3.5 to 14 kW cabinet
3ph
Max 6
95 mm2
Six slot, max 21 kW cabinet
3ph
Max 8
70 mm2 or
1 x 95 mm2
Eight slot, max 28 kW cabinet.
Dual cable for 24/36/48Vdc single
cable for 72/80Vdc
1. Features ...................................................................................
2
2. Technical Information ..............................................................
2
3. Safety Precautions ..................................................................
3
4. Installation ...............................................................................
4
5. Operating Instructions ............................................................
4
6. Menu and Display Information ..............................................
6
7. Service and Troubleshooting ..................................................
7