background image

E V   P O R TA B L E   C H A R G E   C A B L E

M O B I   B O X

Manual

Содержание MOBI BOX

Страница 1: ...E V P O R TA B L E C H A R G E C A B L E M O B I B OX Manual ...

Страница 2: ...NTS IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 OPERATION 6 FRONT PANEL DISPLAY 7 SPECIFICATIONS 8 MAINTENANCE 9 FCC INFORMATION 9 WARRANTY INFORMATION 10 CONTACT CUSTOMER SUPPORT 11 ...

Страница 3: ...actices for preventing accidents Safety Guidelines Use this Charge Cable to charge electric vehicles equipped with a conductive charge port only See the vehicle s owner s handbook to determine if the vehicle is equipped with a conductive charge port Make certain the Charge Cable s supply cable is positioned so it will not be stepped on tripped over or otherwise subjected to damage or stress There ...

Страница 4: ... open or show any other indication of damage If the plug provided does not fit the outlet do not modify the plug arrange for a grounded outlet to be installed by an electrician The charge cord is provided with a grounding conductor and a grounding plug This plug must be plugged into a properly grounded outlet in compliance with national and local electrical codes Warning If at time you think the e...

Страница 5: ...proper outlet installed by a qualified electrician Note The charge cord used to charge the vehicle is a high powered electrical device During normal operation the 230V plug of the charge cord may feel warm The 230V plug must fit tightly into an 230V wall socket that is in good condition Warning Using the charge cord with a worn or damaged 230V wall socket may cause burns or start a fire Periodical...

Страница 6: ... the vehicle connector first then remove the plug from the wall socket Note For charge cables with a Schuko wall plug you can choose between 6A 10A and 13A For charge cables with a CEE wall plug you can choose between 6A 10A and 16A ERROR NOTIFICATION In case of earth failure the Fault LED lights up red immediately after the wall plug is plugged into the wall socket To avoid the error the wall soc...

Страница 7: ...7 Mobi Box front panel Schuko version Mobi Box front panel CEE version FRONT PANEL DISPLAY ...

Страница 8: ...hase blue or Schuko Voltage Wiring 230V AC single phase 50Hz Charge Current max 16A IEC 60309 or 13A Schuko Earth leakage protection AC 30mA DC 6mA Protection under and overvoltage overcurrent Grounding safety earth wire detection Dimensions 215x110x50 mm Weight 4 kg incl 5m cable Operating temperature 25ºC to 40ºC Protection IP44 ...

Страница 9: ... interference and 2 This device must accept any interference received including interference that may cause undesired operation This product has been designed to protect against Radio Frequency Interference RFI However there are some instances where high powered radio signals or nearby RF producing equipment such as digital phones RF communications equipment etc could affect operation If interfere...

Страница 10: ... be either new or reconditioned at Ratio Electric B V discretion This limited Carry In Warranty does not include service to repair damage from improper installation improper connections with peripherals external electrical fault accident disaster misuse vandalism unauthorized alteration or repair abuse or modifications to the product not approved in writing by Ratio Electric B V Any evidence of an...

Страница 11: ...11 CONTACT CUSTOMER SUPPORT Ratio Electric B V Ambachtsstraat 12 3861 RH Nijkerk The Netherlands Tel 31 33 2452360 Fax 31 33 2453154 info ratio nl www ratio nl ...

Страница 12: ...PORTABLE CHARGER MANUAL ART NR 3701 ...

Отзывы: