3.0 SPECIFICATIONS

Model 

PR SERIES (Model numbers beginning with “PRA”)

Operating Pressure 

10,000 PSI (700kg/cm²)

Motor Rating 

Air Motor 50 CFM 80 PSI

HP Reading (PSI) 

60 ton = 6,000, 100 ton = 9,700, 150 ton = 10,200, 200 ton = 10,200

Maximum Operating Temperature 

170º F

Oil Capacity 

5 Gallons

4.0  INITIAL INSTALLATION BEFORE OPERATING 

SYSTEM

4.1 Working Pressure

The factory preset system pressure for 60 ton is 6,000 psi, 100 
ton is 9,700 psi, 150 ton is 10,200 psi, and 200 ton is 10,200 psi.

4.2 Adding Oil

The unit is shipped with the correct amount of oil. Verify oil level 
before  by  removing  the  OIL  FILLER  CAP  and  add  ENERPAC 
HF hydraulic oil into reservoir if necessary. Oil level should not 
exceed 1" from the reservoir top plate cover.

Oil Filler Cap

WARNING: Loose or improperly threaded fittings can 
be  potentially  dangerous  if  pressurized,  however, 
severe  over  tightening  can  cause  premature  thread 

failure. Fittings need to be tightened secure and leak free. Never 
hold or stand directly in line with any hydraulic connections while 
pressurizing. Never grab, touch or in any way come in contact 
with  a  hydraulic  pressure  leak.  Escaping  oil  can  penetrate  the 
skin and a serious injury can result.

4.3 How to Use The Handle Assembly

1.  Push  lever  (callout  #1)  to  release 

locking pin.

2.  Raise  handle  assembly  (callout  #2) 

upward  and  pull  handle  assembly 
(callout  #1)  to  engage  lock  pin  into 
desired hole setting.

3.  Pow’r-Riser  can  now  be  pushed  or 

pulled (be mindful walking backwards) 
to work area.

4.  If  necessary,  the  Pow’r-Riser  should 

be picked up by the lifting bar, or by 
the  eyebolt  for  higher  ton  models 
(callout  #3). 

Never  attempt  to  pick 

jack up by handle assembly.

4.4 Using the Jack For The First Time

1.  Locate  the  valve  control  and  make  sure  it’s  in  the  neutral 

or  center  position  (note:  solenoid  valves  are  in  the  center 
or neutral position when the button(s) are not depressed on 
pendant).

2.  Connect  an  Air  Source  to  the  AIR  SUPPLY  VALVE  

(callout #4).

3.  Open the AIR SUPPLY VALVE (callout #4) on the unit to turn 

the motor “on”. Check for any leaks, repair as needed.

Shift the control valve to the advance and retract position and 
look  for  movement  in  cylinder.  Check  for  any  leaks,  repair  as 
needed. For solenoid operation, use pendant control to operate 
cylinder movement.

                

Air Supply Valve

Figure 3

5.0 OPERATION

5.1 Control Valves: (See Figure 4)

4-Way Manual Valve
• 

Shifting lever to right directs pump output to advance port

• 

Shifting lever to left directs pump output to retract port

• 

Center  position  is  neutral/hold.  Pump  output  is  directed 
back to tank

4-Way Solenoid Valve 
• 

To Advance……depress button to the ADV (UP) position

• 

For Neutral/Hold……release button(s)

• 

To Retract……depress button to the RET (DOWN) position

Figure 2

Figure 1