5.4 Jacking Safely

You must know the weight of what you intend to lift and choose 
a jack with at least 20% more capacity.

WARNING:  Never  crawl  or  place  any  part  of  your 
body under any load at any time.
 Insert lock rings as 
you lift. Jacks are meant for lifting only and should not 

be used to support the load for any period of time.
You  should  obtain  and  be  familiar  with  the  American  National 
Standards Institute rules that apply to hydraulic rams and jacks 
(ASME ANSI B30.1).

5.5 After Completing the Job

Fully retract the cylinder, close air valve (#4) to shut off motor, shift 
the hydraulic controls several times to release system pressure. 
Store the unit in a clean, dry area.

6.0 MAINTENANCE

6.1 Periodic Maintenance                                                                

Change the hydraulic oil and clean the oil filter screen and magnet 
(located in the reservoir) twice a year. Use Enerpac HF hydraulic 
oil (model number HF-102 - 5 gallon container). Change the oil 
more frequently when used in extremely dusty areas or when the 
oil has been overheated. Using oil other than Enerpac brand may 
void the pump warranty.

6.2 Maintain Oil Level

Check  hydraulic  oil  level  every  30  hours  of  operation.  Add 
Enerpac  HF  hydraulic  oil  (model  number  HF-101  -  1  gallon 
container) when necessary. Oil level should be no more than 1” 
from top of reservoir plate – with cylinders retracted and motor 
off.
Change oil at least twice a year. The following conditions require 
more frequent oil changes:
• 

Rigorous duty, where oil temperature may reach 150° F.

• 

High  humidity  environment  and  extreme  changes  in 
temperature  that  can  result  in  condensation  inside  the 
reservoir.

• 

Dirty or dusty environments that may contaminate the oil.

• 

Frequent connection and disconnection of hydraulic hoses 
and components.

6.3 Clean Oil Filter Screen Once a Year

Loosen and remove reservoir plate bolts. Lift pump unit off the 
reservoir,  being  careful  not  to  damage  the  gasket.  Unscrew 
screen from bottom of pump unit and clean with nonflammable 
solvent.  Blow  dry  and  reassemble.  Keep  areas  around  pump 
unobstructed  to  provide  good  air  flow  around  the  motor  and 
pump. Keep the motor and pump as clean as possible.

6.4 Flush the Pump

If  you  suspect  your  pump  has  been  contaminated  or  discover 
sludge  or  other  deposits  on  internal  components,  you  should 
thoroughly flush the pump. Remove the old oil from the reservoir, 
then  thoroughly  clean  the  reservoir  and  refill  with  a  clean, 
nonflammable flushing oil. Reassemble the pump and motor to 
the reservoir.
Now  run  the  pump  in  no  load  condition  for  1  or  2  minutes 
maximum. Unplug the pump and remove the motor and pump 
assembly again. Now drain the flushing oil and re-clean the inside 
of  the  reservoir.  (Make  sure  flushing  fluid  is  also  drained  from 
pump assembly). Refill the reservoir with Enerpac HF hydraulic 
oil and reassemble the pump.

6.5 Air Motor and Filter Lubricator

The air motor is a precision built rotary motor. The top clearance 
(between  rotor  and  bore)  is  .0015".  The  total  end  clearance 
(between the sides of the rotor and the end plates is .002". The 
vanes take up their own wear and will last 5,000-12,000 hours, 
depending  upon  speed,  method  of  oiling,  operating  pressure, 
and  lend  itself  to  operating  pressure  above  100  psi  (6.89  bar-
metric). Allowing excess moisture or foreign particles from the air 
line to enter the motor will void the Enerpac warranty.
A moisture trap and filter has been installed in the air line ahead 
of motor. For efficiency of output and control of speed, use air 
line of not less then ¾ in pipe size. When coupling or connecting 
the motor to a drive member, avoid any end or side thrust on the 
output shaft and especially DO NOT HAMMER ON SHAFT.
The starting torque is less than the running torque and could vary 
depending on the position at which the vanes stop in relation to 
the air intake port. The speed and torque can be regulated by 
using a pressure regulator or a simple shut-off valve. Lubrication 
is  necessary  for  the  shaft  seal,  and  rust  prevention.  Each  air 
powered  jack  is  equipped  with  an  automatic  air  line  oiler  set 
to  feed  1-3  drops  per  minute.  Use  Kilfrost  400  pneumatic  tool 
lubricant or equivalent. Excessive moisture in the line can cause 
rust formation in the motor and might also cause ice to form in 
muffler due to expansion of air through the motor.