There may be cases when the number of outlets needed for
heating is significantly different than the amount needed for
cooling. This is usually caused by a large appliance load or an
excessive amount of windows. In cooling mode the outlets must
be in the fully open position or there will be a loss in system
performance. The vents may need to be partially closed in
heating mode, or it may be necessary to close off some of the
outlets. The Rough-In Boots have built in dampers and can be
adjusted for room comfort. Use the damper key supplied from
Energy Saving Products for easy vent adjustments.
It is recommended to have a service contractor perform
a system check in both spring and fall for the cooling and
heating season, on your entire HVAC system. For any secondary
components such as boilers, geothermal, tankless heaters,
condensing units etc., contact the manufacturer for any
maintenance recommendations.
When it comes to servicing the Hi-Velocity HE-B System itself,
only the 1” air filter requires maintenance on a regular basis.
With a clean air filter, you not only have cleaner air to breathe,
but you will also help maintain unit efficiency, and increase
operating life. Ensure that there is always a filter in place, and
check every month to ensure that the filter is clean. To clean the
filters, remove from system, wash the white side and vacuum the
colored side. Once the filter has been washed, vacuumed and
completely dried, replace in system (colored side to face the fan
coil). The amount of time between filter changes/cleaning will
be dependent upon the living habits of the homeowner. It is
recommended to replace the filter at least annually.
Maintenance
Hi-Velocity Outlets
Hi-Velocity HE-B User Guide
Hi-Velocity Air Purification System (HE PS)
The optional Hi-Velocity Air Purification System comes with
a built-in Remote Mounted Service Panel to automatically keep
track of service intervals. Indicator lights will tell you when to
change the filter and ultraviolet lamps 30 days in advance.
Because of the high speed of the airflow in the supply air
ductwork of the Hi-Velocity System, the cleaning of these ducts
is not a requirement.
Duct Cleaning
Please note that a dirty filter will
increase motor power draw, and
may reduce air flow and system
performance.
Periodically, the vent plates may need to be cleaned due to
dust statically attracted to the grid insert of the vent plate. The
grid insert or the whole vent plate can be removed and washed
with soap and water.
Vent Cleaning
For Cooling Systems Only
When located in an unconditioned space (crawl space or
attic), all the vent outlets must be closed and the return air
blocked during winter shutoff times unless the constant fan is
being used, to prevent condensation in the ductwork.
If a vent outlet has been installed in a location that is
bothersome to the occupant, an optional directional louvered
grill is available from the manufacturer. This grill can easily be
inserted in place of the standard grill insert, and will direct air
away from the occupied area. For information on how to obtain
louvered grills visit the website at www.hi-velocity.com to find
the vendor closest to you, or contact the factory toll-free at
1-888-652-2219
Directional Grill Option
Module HEB COM
Commissioning & User Guide (7/8)