WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness. Never operate the HEPS System out of the ductwork. Avoid touching the glass portion of the lamp with your hands.
Fig. 4 Transition
(Top View)
HEPS
RPM-E-70
50/70 Fan Coil
Block air flow
with 18 ga.
sheet metal
Top View
Fig. 5 Block Air Flow
(Top View)
5.
Tape all seams between the air handler and the outlet
side of the HEPS so there can be no air bypassing the
system.
6.
Attach the air handler to the outlet side of the HEPS and
fasten with #10 x 3/8 self-drilling sheet metal screws.
NOTE: Only 1/2 inch of clearance has been provided
between the outer and inner case.
7.
Slide the components into the outer case and tighten
locking knobs finger tight. Make sure the inner module will
freely slide in and out of the outside enclosure.
8.
Plug in the power cord to any 120vac outlet and check
both sight ports to make sure both lamps are illuminated.
Ultraviolet lamps must remain on at all times regardless of
thermostat or AirCycler settings.
9.
Set the thermostat or the
AirCycler to operate the
fan unit for at least 25 minutes every hour. If air quality
problems persist after one week, increase the fan unit
operating time by (5) minute intervals.
Top View
RPM-E-70
Create transition
from 18 ga.
sheet metal
HEPS
Transition
Transition
50/70 Fan Coil
Service
MERV-13 Filter: Change every
6 months
Ultraviolet Lamps: Change every
12 months
Operation
Only operation of the air-handler fan unit is required for
air purification and sterilization to take place.
Note: The ultraviolet lamps are wired to operate
continuously. This feature allows the catalyst to burn off
surface impurities, cleaning and reactivating itself during
periods of non-use or no airflow.
Replacement Filters and Ultraviolet Lamps
Replacement components are available in the form of
a replacement kit containing (2) filters and (1) set of UV
lamps. Replacement kits are available from your local
HVAC wholesaler or contractor.
The HEPS System combines
three unique technologies
to protect people against indoor air pollutants.
Photocatalytic Oxidation (PCO)
technology combined
with high efficiency
electrostatic MERV-13 particulate
filtration
and
germicidal ultraviolet light
quickly
reduces toxic gasphase chemicals, lung damaging dust
and airborne germs from the living environment.
Many new homes have smart programmable thermostats
that allow for automatic operation of the air-handler
fan unit when there is no demand for heating or air
conditioning. It is important that the HEPS is operating
at least
(30) minutes per hour (24) hours per day
to
remove toxic materials from the indoor environment.
The length of operation depends on the location of the
home or office in relation to point source pollution such
as refineries, processing plants, automobile traffic and
areas that produce high levels of pollen. Individuals that
are sensitive to mold spores, dust mites, chemicals or
have respiratory problems such as asthma, emphysema,
and chronic allergies should extend the run time to (40)
minutes or more per hour.