Troubleshooting Guide 

 

Unit does not burn properly 

 

1.  Check the wood; it must be dry.  If moisture 

is sizzling out the end, the wood is too wet. 

 
2.  Test the draft.  It should be .05/.06 (inches of 

water column).  

 
3. Check to maker sure the flue is not 

obstructed. Also check the baffle area in the 
unit for excessive ash buildup. 

 
4.  Check the airflow in the room.  If it is too air- 

tight, the unit cannot get enough combustion 
air to burn properly. You may need to bring 
outside air to the furnace or stove. 

 
5.  Check the chimney and stovepipe.  They 

need to be airtight to make the unit draft 
properly. 

 
6.  Check that only one appliance is hooked to 

the chimney. 

 
7.  Check the chimney for a downdraft. A cold 

chimney will keep flue gases from rising up 
the chimney.  Proper insulation of chimney 
and/or installing a stainless steel liner sized 
for the unit may remedy the problem. 

 
8.  Check your chimney for downdraft caused 

by taller surrounding trees or buildings.  The 
chimney may have to be extended or a 
chimney vent cap installed. 

 
9.  Check all gaskets for leaks: Door gaskets, 

glass gaskets, ash drawer or door gaskets 
(where applicable). 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit does not give off enough heat 

 

Is the unit installed correctly? 
1.  Check to see if the unit has an adequate 

cold air return or inadequate hot air outlet. 

 
2. Room may be too airtight, inadequate 

combustion air or return air. 

 
3.  Flue draft may be inadequate or too strong - 

.05/.06 (inches of water column) 
recommended. 

 
4.  Door gaskets may be leaking.  In addition, 

glass gaskets, ash drawers or door gasket 
should be checked for leakage. 

 
5.  Check flue.  Make sure it is not obstructed. 
 
6.  Check ductwork for leaks – cold and hot air 

ducts.

 

 
 

Unit is making noise/distribution blower is 
vibrating

 

 
With electrical power disconnected

, check the 

following: 

 

1.  Check for loose parts. 
 
2.  Is the blower wheel contacting the housing? 

If so, realign or replace as required. 

 
3.  Is foreign material inside the housing? 
 
4.  Is there a leak in the ductwork or is there 

loose ductwork? 

 
5.  Does the blower wheel/motor need to be 

cleaned or serviced? 

 
6.  Is the blower wheel set screw loose? If so, 

secure it properly. 

 

Maintenance of blower assembly

:

 After 

disconnecting the power source

 – 

a)  Remove dirt from blower wheel and 

housing. 

b)  Check tightness of wheel set screw. 
c)  Check the wiring to see if it is secure and 

well insulated. 

d)  Lubricate the motor according to the 

manufacturer’s instructions.  Remove 
any excess lubricants. 

Rev 06/2007 

19

Содержание Silhouette 2800

Страница 1: ...SILHOUETTE 2800 2850C Zero Clearance Wood Fireplace Installation and Operation Manual RJM Manufacturing Inc P O Box 27 1875 Olson Drive Chippewa Falls WI 54729 715 720 1794 Fax 715 720 1797...

Страница 2: ...ireplace is designed for a lifetime of durable reliable performance and easy operation This manual describes the installation and operation of your Energy King factory built fireplace Be sure to read...

Страница 3: ...top 10 TYPES OF WOOD 10 WARNINGS 11 INITIAL FIRE 12 STARTING A FIRE MODEL 2800 12 OPERATING SILHOUETTE MODEL 2850C 13 What is a Catalytic Woodstove 13 Using a Catalytic Woodstove 13 Troubleshooting th...

Страница 4: ...and cleaned regularly A High Temperature Listed Chimney is required 8 Do not connect your solid fuel appliance to a chimney flue already venting another appliance 9 Dispose of cool ashes with care Sto...

Страница 5: ...e thermostatically controlled blower has manual and automatic controls see Figure 6 Lower Grill Provides access to blower draft control and ash pan Keep area accessible This grill also allows cool air...

Страница 6: ...st be in the fireplace at all times when in operation Without this damage will occur Next insert the D brick 9 x 4 x 1 in the brick baffle The bricks are held in place by a slot in the back of the fir...

Страница 7: ...an optional 200CFM Blower This can be installed by lowering the grill and placing the blower under the firebox on the right side A tie strap is provided to clamp the blower assembly in place Make sur...

Страница 8: ...ilt fireplace on a combustible floor is approved as long as an area extending 16 in front of and 8 to each side of the fuel opening is protected Insulate this area with non asbestos millboard or equiv...

Страница 9: ...l To Mantel Optional Remote Outlet Grills from Ceiling Faceplate to Sidewall Duct Boots to Framing Side Wallboard to Faceplate Edge Perimeter 0 0 2 0 0 11 11 8 2 1 0 Unit Height Unit Width Unit Depth...

Страница 10: ...e sides and back are 0 clearance to combustibles from the standoffs and open from the top of the unit to the ceiling Do not remove standoffs from the units Studs and sheeting must be kept 0 from these...

Страница 11: ...he first 2 x 4 on edge with the second 2 x 4 laying flat The studs are placed vertically over the header working from the center of the fireplace outward space first stud 8 from the center This will g...

Страница 12: ...e and 2 above any obstructions within 10 see Figure 14 below The minimum draft of the fireplace is 06 of water column A straight chimney is best Up to two 30 degree elbows can be used for offsets Figu...

Страница 13: ...woods such as ash beech birch maple and oak are denser and provide a longer lasting fire Season your wood Allow wood to dry out reducing water content in wood for at least one year Purchase or cut woo...

Страница 14: ...he fireplace door is closed check for the following causes 1 Proper draft has not had time to establish Open draft control 2 Blockage in the fireplace stovepipe or chimney 3 Leaks in the chimney 4 Col...

Страница 15: ...per on the firebox floor and cover with dry kindling Open the draft control completely and light the fire Draft control is located above the glass door After a fire is established add more dry wood an...

Страница 16: ...ll rod Your Energy King stove is equipped with a bypass mechanism located above the door The bypass allows you to bypass the smoke around the combustor when you do not have the necessary 500 degrees t...

Страница 17: ...Burn only dry seasoned wood Lightly brush the the catalyst such as heavy papers wet face of the combustor with a soft bristle brush wood garbage etc such as a paintbrush to remove the accumulation The...

Страница 18: ...pplied Ceramics Warranty for information on replacement Figure 16 The Energy King fireplace has two catalytic combustors To replace combustors look up inside the stove and locate the catalytic combust...

Страница 19: ...ve gas temperatures reach 600 degrees F within two or three minutes after a fire is started if the fire is allowed to die down immediately it may go out or the combustor may stop working Once the comb...

Страница 20: ...on t touch the glass In case of breakage glass must be replaced with a high temperature glass such as Robax Tempered or ordinary glass will not withstand the high temperatures of the Energy King firep...

Страница 21: ...clean soft surface such as a towel Find the ends of the gasket and pull it off Take a screwdriver and remove excess gasket glue from the channel Take new stove gasket cement available at your local w...

Страница 22: ...plicable Unit does not give off enough heat Is the unit installed correctly 1 Check to see if the unit has an adequate cold air return or inadequate hot air outlet 2 Room may be too airtight inadequat...

Страница 23: ...tatic pressure too low Check and correct system 5 Thermostat is not opening damper or turning on forced draft fan a Check wall thermostat b Check the thermostat wires possible short or broken wire c C...

Страница 24: ...ican Heritage Dictionary Second College Edition Cat a lyst n 1 Chem A substance usually present in small amounts relative to reactants that modifies and especially increases the rate of a chemical rea...

Страница 25: ...ires more heat restart the fire with kindling as always but add smaller fuel loads This allows your stove to operate at maximum efficiency and with minimum emissions Avoid the temptation of building a...

Страница 26: ...thing I should consider R The woodstove and chimney work as a system It is important that the stove s chimney system be sized properly according to the manufacturer s instructions Whether venting int...

Страница 27: ...red by this warranty This limited warranty does not apply If your appliance has not been installed operated and maintained in strict accordance with instructions provided in the Installation Operation...

Страница 28: ...Y KING dealer in your area contact RJM Manufacturing Inc directly Provide your name address phone number serial number and model number of the Fireplace date of purchase name and address of installer...

Страница 29: ...replacement at the following special price schedule Year 4 85 00 Year 5 95 00 Year 6 105 00 Year 7 and after at current retail price Conditions 1 2 and 3 also apply to the Prorated portion of the warr...

Отзывы: