Rev 07/13/09
ENERGY KING™ Wood/Coal Boiler Owner’s Manual
U. S.
12
Installation
Assembling Your ENERGY KING Wood/Coal Boiler
The entire installation should be planned before putting the Boiler in place to ensure compliance
with all the requirements outlined in the owner’s manual.
Your new ENERGY KING Wood/Coal Boiler will have been shipped on a pallet with several boxed
components that will need to be assembled prior to installation. Please see “Components” for a list
of everything that was shipped along with your ENERGY KING Wood/Coal Boiler.
Once your Boiler is placed in your desired location:
1. Remove the protective plastic coating from
the outer cabinet of the heating appliance
before assembling.
2.
Cast Iron Hearth Plates.
Position front and
rear cast iron hearth plates in burn chamber.
Your primary type of fuel (wood or coal) will
determine how to position the hearth plates.
The purpose of proper location is to
introduce the precise amount of combustion
air into the burn chamber to promote the
most efficient combustion for either fuel.
The words “Wood” and “Coal” are cast into
the hearth plates on opposite sides.
a. If you are going to burn wood, position
the hearth plates with the word “Wood”
facing out, not into the burn chamber.
b. If you plan to primarily burn coal,
position the hearth plates with the word
“Coal” facing out.
3.
Firebrick.
The firebrick in your ENERGY
KING heating appliance will have been
installed at the factory; however they may
have shifted during shipment. If adjustments
are needed, position the firebrick by standing
up on end on the left and right sides of the
burn chamber.
ENERGY KING A40EKB and 35EKB Boilers
use 12 firebricks (6 on each side). ENERGY
KING 45EKB Boilers use 14 firebricks (7 on
each side).
4.
Cast Iron Doors.
Mount the fuel loading
door and ash removal door on the front of
the heating appliance and secure with the
enclosed door pins (4 included).
5.
Control Box.
a. Remove the control box cover. See
Figure 3: Control Box for Forced Air Draft.
b. Mount the control box on the lower left
side of the heating appliance using the
screws provided.
Do not connect power to your
ENERGY
KING
Wood/Coal Boiler until the
installation is complete.
Содержание 35EKB
Страница 2: ......
Страница 4: ......
Страница 8: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 2 This page is intentionally left blank...
Страница 42: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 36 This page is intentionally left blank...
Страница 43: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 37 Appendix A Wiring Diagram...
Страница 44: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 38 This page is intentionally left blank...
Страница 46: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 40 This page is intentionally left blank...
Страница 50: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 44 This page is intentionally left blank...
Страница 54: ...Rev 07 13 09 ENERGY KING Wood Coal Boiler Owner s Manual U S 48 This page is intentionally left blank...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 71: ......
Страница 72: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......