14) Install and Tension the Cartridge Sup-
port Cables
There are six cartridge support cables. Install the cables
as shown in Figure 21.
Attach thimble end of all cartridge support cables to the
intermediate frame using the provided shackles. Pass the
stud end of the cable through the corresponding cartridge
chain loop, and attach as shown in Figure 21 using a die
spring, washer and nuts.
To properly tension the cartridge support cables, tighten
the first nut on one cable until all slack is removed, then
tighten it until the tensioning springs have been com-
pressed to 32 mm [1 ¼"] in height. Lock this nut in place
with the second "jam" nut. Repeat this procedure with
the other cables.
15) Adjust the Height and Levelness of the
System Frame
Verify that the system frame is 305 ± 25 mm [12" ± 1"]
from the ground at the front and rear of the system. It
may be necessary to add shims to the socket hitch in
order to adjust the levelness of the cartridge. See Fig-
ures 21 & 21a.
SHACKLE
CARTRIDGE
SUPPORT CABLE
32 mm [1 1/4"]
WASHER
NUTS
Figure 21
305 mm ± 25 mm [12" ± 1"]
SOCKET HITCH
SHIMS MAY BE ADDED OR REMOVED
HERE AS NECESSARY TO ACHIEVE
LEVELNESS OF SYSTEM
SEE DETAIL 21a
Detail 21a
305 mm ± 25 mm [12" ± 1"]
CARTRIDGE
SUPPORT CABLE
INTERMEDIATE FRAME