Light commercial(High ESP Duct 196Pa) Service Manual
5
1.3 Function introduction
Function
Type
Function Item
48
60
Protection
High pressure protection
○
○
Low pressure protection
○
○
Compressor overloading protection
○
○
High exh. temperate protection
○
○
Phase protection
(Phase-loss, phase- reverse)
○
○
Over-heating protection
○
○
Anti-freezing protection
○
○
Sensor failure alarm
○
○
Failure code display
○
○
Comfort
Cooling
○
○
Heating
○
○
3-Speed
○
○
Adjustable ESP
-
-
Auto-restart
○
○
Anti-cold wind
○
○
Afterheat wind blowing
○
○
Timing ON/OFF
○
○
Operating
Time display
○
○
Operation mode display
○
○
Fan speed display
○
○
Defrost display
○
○
Timing ON/OFF display
○
○
Wind angle display
-
-
Sleeping mode display
○
○
Running
Auto start
○
○
Dehumidifying
○
○
Auto defrost
○
○
Ventilation function
○
○
Low ambient temperature cooling
○
○
Health
Washable air filter
○
○
Fresh air interface
-
-
Installation
Left/right drainage
-
-
Left/right pipe connection
-
-
Down/back air suction
-
-
Installation indicating board
-
-
Two kinds of static
pressure adjustable
-
-
Note
:
○
means have this function
-
means don’t have this function
Содержание SAD48HD1-A
Страница 18: ...Light commercial High ESP Duct 196Pa Service Manual 17 3 2 Outdoor Unit SAU48U1 A SAU60U1 A...
Страница 33: ...Light commercial High ESP Duct 196Pa Service Manual 32...
Страница 35: ...Light commercial High ESP Duct 196Pa Service Manual 34...
Страница 37: ...Light commercial High ESP Duct 196Pa Service Manual 36...
Страница 56: ...Light commercial High ESP Duct 196Pa Service Manual 55...
Страница 58: ...Light commercial High ESP Duct 196Pa Service Manual 57 Communication failure between indoor and outdoor unit...
Страница 59: ...Light commercial High ESP Duct 196Pa Service Manual 58...
Страница 60: ...Light commercial High ESP Duct 196Pa Service Manual 59 Outdoor protection phase sequence...
Страница 61: ...Light commercial High ESP Duct 196Pa Service Manual 60 Cooling high pressure protection...
Страница 62: ...Light commercial High ESP Duct 196Pa Service Manual 61 Heating high pressure protection...
Страница 63: ...Light commercial High ESP Duct 196Pa Service Manual 62...
Страница 64: ...Light commercial High ESP Duct 196Pa Service Manual 63 Cooling low pressure protection...
Страница 65: ...Light commercial High ESP Duct 196Pa Service Manual 64 Heating low pressure protection...
Страница 66: ...Light commercial High ESP Duct 196Pa Service Manual 65...
Страница 67: ...Light commercial High ESP Duct 196Pa Service Manual 66 Cooling exhaust temperature protection...
Страница 68: ...Light commercial High ESP Duct 196Pa Service Manual 67 Heating exhaust temperature protection...
Страница 70: ...Light commercial High ESP Duct 196Pa Service Manual 69 Sensor failure protection...
Страница 71: ...Light commercial High ESP Duct 196Pa Service Manual 70...
Страница 73: ...Light commercial High ESP Duct 196Pa Service Manual 72 5 2 2 Air conditioner operates but effect is terrible...
Страница 74: ...Light commercial High ESP Duct 196Pa Service Manual 73...
Страница 75: ...Light commercial High ESP Duct 196Pa Service Manual 74...
Страница 76: ...Light commercial High ESP Duct 196Pa Service Manual 75 5 2 3 Abnormal sound or viberation...
Страница 77: ...Light commercial High ESP Duct 196Pa Service Manual 76...
Страница 78: ...Light commercial High ESP Duct 196Pa Service Manual 77...
Страница 79: ...Light commercial High ESP Duct 196Pa Service Manual 78 5 2 4 Abnormal odor...
Страница 80: ...Light commercial High ESP Duct 196Pa Service Manual 79 5 2 5 Air switch action when air conditioner starting up...
Страница 81: ...Light commercial High ESP Duct 196Pa Service Manual 80 5 2 6 Air conditioner water leakage...