No.

Hazard

Description

STEP 1

Potential Source

Potential 

Consequences

Inherent 

Risk

STEP 2

Controls

STEP 3

Residual 

Risk

STEP 4

5

Explosive gas 

hazards 

Explosive gas 

generated by batteries:

• 

Inadvertent ignition 

of flam-mable gas.

Burns to eyes and skin:

• 

Secondary injuries 

as a result of 

explosions.

_______

6

• 

Follow manufacturers 

advice on Installation 

and maintenance 

activities.

• 

Inspect equipment 

for damage before 

installing.

_______

6

6

Toxic fumes 

hazards

Consult manufacturer for 

advice on Toxic fumes 

generated from different 

types of batteries in: 

• 

Normal operation.

• 

Fault conditions.

Consult manufacturer 

for advice on: 

• 

Poisoning

• 

Asphyxiation

• 

Burns to airway 

tissues (e.g. from 

corrosive gases).

 

• 

Other 

consequences.

_______

7

• 

Follow manufacturers 

advice on Installation 

and maintenance 

activities.

• 

Inspect equipment 

for damage before 

installing.

_______

7

This hazard should be considered for all CEC approved pre-assembled integrated Battery Energy Storage Systems (BESS) 

where the installer is required to make connections on the DC side of the system (e.g. connecting equipment that is delivered to 
site as two or more modules) should be considered for each individual situation. 

Site specific sources of hazards (e.g. impact from vehicles), should be considered for each individual situation. 

Site specific sources of consequences (e.g. damage to battery system, creating toxic fume or other hazards) should be 

considered for each individual situation.

Site specific sources of controls (e.g. bollards) should be considered for each individual situation.

Material Safety Data Sheets shall be provided at the completion of installation (refer to AS/NZS 5139:2019 Clause 6.4.1).

Contact your manufacturer to determine the risk level for this hazard. Follow the manufacturers advice on installation and 

maintenance activities and install and inspect any equipment for damage before installation. Installers will also be required 
assess site considerations to determine the inherent risk rating and the residual risk.

Contact your manufacturer to determine the risk level for this hazard. Follow the manufacturers advice on installation and 

maintenance activities and install and inspect any equipment for damage before installation. Installers will also be required 
assess site considerations to determine the inherent risk rating and the residual risk.

Risk Assessment Form Columns Hazard description: as described in AS/NZS 5139:2019. 
Potential source: any or reasonably foreseeable abnormal conditions or reasonably foreseeable misuse.
Potential consequences: the most likely outcome.
Inherent risk: cross-referencing the consequence against the likelihood of it occurring in the risk matrix (before the controls 
are implemented).
Controls: should consider the hierarchy of control methods described in the relevant OHS/WHS Regulations and AS/NZS 
5139:2019.
Residual risk: cross-referencing the consequence against the likelihood of it occurring in the risk matrix (after the controls 
are implemented).

Notes:

Содержание Homepower HP-6M Series

Страница 1: ...OWNER S MANUAL HP 6M Main Unit HP 6S Sub Unit...

Страница 2: ...Neither 8 Star Energy Pty Ltd nor Energizer Brands LLC is affiliated with the respective owners of their trademarks To secure the full 10 year Product Warranty Energizer Homepower HP 6 Series must be...

Страница 3: ...om de energization EARTH This indicates location of grounding point on the equipment LOCKING POINT This indicates location of locking point on the equipment EUROPEAN CONFORMITY This indicates that the...

Страница 4: ...the internal or external components including the exterior casing Do not sit on step on place objects on or insert objects into Energizer Homepower HP 6 Series units Please refrain from placing liqui...

Страница 5: ...Energizer Homepower HP 6 Series is modular and consists of the Main Unit HP 6M and up to 3 optional Sub Units HP 6S The Energizer Homepower HP 6 Series measures solar generation energy consumption usi...

Страница 6: ...time When there are no instructions for the Scheduler entered for a window of time then the unit will revert to Automatic Mode until it reaches a window of time with instructions a Automatic mode logi...

Страница 7: ...phase L N PE Inverter Nominal Output Voltage V 230 V a c Nominal AC Frequency Hz 50 Hz Self Adapting PF Range 1 adj 0 8 leading 0 8 lagging Nominal Power W 3600 W Nominal AC Current A 16 A Cooling Nat...

Страница 8: ...ergy 1 4G LTE The HP 6M supports only one method of communication at any one time ensure that an appropriate method is selected either 4G LTE Wi Fi or Ethernet depending on the site conditions In area...

Страница 9: ...e or password has been changed please follow the steps below to help reconfigure the connection This process can be done through a smart phone tablet or computer and the steps are the same no matter w...

Страница 10: ...spective operating state i e fault as described in Table 2 on page 13 If this is the case refer to the Energizer Homepower App or Customer Portal to identify the system issue and resolve fault If you...

Страница 11: ...s At this stage you have powered off the Energizer Homepower HP 6 Series systems DANGER Please do not attempt to disassemble the HP 6M or HP 6S in any way as it may cause damage to the product Unsoli...

Страница 12: ...off the AC Isolators connected to the HP 6M unit within the switchboard Stop the source of water leakage by redirecting flow and or contacting plumbing services In case the unit is submerged do not a...

Страница 13: ...may occur by eye contact skin contact and ingestion EXEMPT FROM CLASSIFICATION ACCORDING TO AUSTRALIAN WHS REGULATIONS Further this product meets the definition of an Article Under the Globally Harmo...

Страница 14: ...absorbent or sand Ensure that clean up procedure does not expose the spilled material to the moisture Containerize and place all leaking batteries in individual containers that are leak proof non con...

Страница 15: ...ivity contact with incompatible substances can cause decomposition or other 9 1 Appearance lithium ion batteries enclosed within protective metal case 9 2 Nominal Voltage 51 2V 9 3 Rated Capacity 120A...

Страница 16: ...n EC No 1907 2006 annex XIII When promptly and safely used or disposed the battery does not present any environmental hazard While disposing please ensure that it is disposed in accordance with local...

Страница 17: ...ery Storage only includes battery module and BMS B1AU0010020000 Date of Effect Aug 28th 2020 This limited manufacturer s Warranty applies to the residential application of the Energizer Homepower HP 6...

Страница 18: ...t owner s manual Any attempt at modifying the product whether physically or by means of software programming without the express consent of Entel Removal and relocation of your product to a different...

Страница 19: ...a business then the consumer guarantees act 1993 shall not apply Your rights under New Zealand Consumer Law may also apply to any repaired or replacement product 9 RMA Process In order to make a claim...

Страница 20: ...Medium No Hazard Description STEP 1 Potential Source Potential Consequences Inherent Risk STEP 2 Controls STEP 3 Residual Risk STEP 4 2 Energy hazards1 Arc flash from insufficient isolation or insula...

Страница 21: ...battery system creating toxic fume or other hazards should be considered for each individual situation 4 Site specific sources of controls e g bollards should be considered for each individual situat...

Страница 22: ...Energizer Homepower HP 6 Series Energizer Homepower HP 6 Series Energizer 2021 V23 00211 V23 00211 Energizer 2021 42 43 Notes Notes...

Страница 23: ...energizerhomepower com...

Отзывы: