5.4 AC PARALLEL OPERATION
WARNING!
ONLY CONNECT A PARALLEL CAPABLE EZV SERIES INVERTER
GENERATOR WITH THE APPROVED PARALLEL CABLE. ATTEMPTING TO
CONNECT A DIFFERENT BRAND OR MODEL IN PARALLEL WITH YOUR
GENERATOR WILL VOID YOUR WARRANTY AND COULD CAUSE BODILY
HARM.
DO NOT START THE GENERATORS BEFORE CONNECTING THE PARALLEL
CABLE. IF THE CABLE IS CONNECTED WHILE ONE GENERATOR IS
RUNNING IT WILL BE OVERLOADED AND THE ‘RESET’ BUTTON WILL NEED
TO BE PRESSED.
IF THE OVERLOAD INDICATOR LIGHT STAYS ON AFTER RESETTING THE
GENERATOR STOP THE ENGINE, WAIT FOR 5 MINUTES THEN RESTART IT.
NOTE
For continuous operation do not exceed the combined rated power.
At max output the generators must not run longer than 30 min.
Stop the engine before connecting or removing the parallel cable.
For single unit operation the parallel cable must be removed.
1.
Make sure both generators are OFF.
2.
Connect the terminals of the AC parallel cable to the parallel socket of each
generator.
3.
Start each engine according to ‘Starting the Engine’. Confirm appliances
are turned off, then connect the appliance to the parallel cable.
4.
Turn on the appliance.