Energizer eZV3200P Скачать руководство пользователя страница 11

4

 

 

Lubricate all exposed metal parts regularly. See chapter 7.1 for 
maintenance schedule. 

1.5 OTHER SAFETY TIPS 

WARNING!

 

 

To avoid breathing in poisonous carbon monoxide from the exhaust 
gases, adequate ventilation should be provided if the generator set is 
running in a partially enclosed space. 

 

 

If the generator set is stored outdoors, check all the electrical 
components on the control panel before each use. Moisture can 
damage the generator and can lead to an electric shock. 

 

 

Do not connect an extension to the exhaust pipe. 

 

 

Generators vibrate in normal use. During and after the use of the 
generator, inspect the generator as well as extension cords and power 
supply cords connected to it for damage resulting from vibration. Have 
damaged items repaired or replaced as necessary. Do not use plugs or 
cords that show signs of damage such as broken or cracked insulation 
or damaged blades. 

 

 

If you start to feel sick, dizzy, or weak after the generator has been 
running, move to fresh air RIGHT AWAY. See a doctor. You could have 
carbon monoxide poisoning.

Содержание eZV3200P

Страница 1: ...USER GUIDE SERIES...

Страница 2: ...s known to cause cancer birth defects or other reproductive harm 2018 Energizer Energizer and certain graphic designs are trademarks of Energizer Brands LLC and related subsidiaries and are used under...

Страница 3: ...Thanks for choosing the EZV Series You re excited to power up so we ll keep this brief Let s get started...

Страница 4: ...THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM 263521...

Страница 5: ...that should be followed during installation and maintenance of the generator This user guide covers the safety operation and maintenance procedures for the eZV3200P and eZV3200RV All information in t...

Страница 6: ...equest warranty support in the future Product registration is required for all product support and warranty coverage Warranty support operation assistance and product support is provided by Midland Po...

Страница 7: ...ing the Engine 14 Starting Your Generator 15 5 Generator Use 18 DC Applications 19 AC Applications 20 AC Parallel Operation 21 6 Stopping the Engine 22 7 Maintenance 23 Maintenance Schedule 24 Changin...

Страница 8: ...sonal injuries or equipment damage may result Never run the generator in an enclosed area to avoid harm from exhaust emissions of a poisonous carbon monoxide gas Pay attention to the warning labels Th...

Страница 9: ...that everything is in proper working order Faulty devices or power cords can lead to an electrical shock Turn off the generator immediately if the device begins to operate abnormally Then disconnect...

Страница 10: ...element with flammable liquids like gasoline because an explosion may occur Allow the generator set to cool down and turn off the engine before performing any maintenance Failure to do so can cause s...

Страница 11: ...age the generator and can lead to an electric shock Do not connect an extension to the exhaust pipe Generators vibrate in normal use During and after the use of the generator inspect the generator as...

Страница 12: ...of your generator Going over the terminology below will make sure we re on the same page 2 1 COMPONENT IDENTIFICATION Folding Handle Control Panel Fuel Gauge Battery Maintenance Panel Wheel Air Filte...

Страница 13: ...A Outlets Ground Parallel Socket DC Outlet Circuit Breakers Output Indicator Overload Indicator Low Oil Indicator Electric Start EcoMode Fuel Knob Reset Display Mode 120V 23 3A TT 30 RV Outlet 120V 20...

Страница 14: ...nd the backlight will turn off after 10 seconds Press the DISPLAY button multiple times to cycle through different information displays The display is only powered while the unit is running EcoMode Ec...

Страница 15: ...gine using the electric start system ON Switch must be in this position to recoil or remote start STOP Stops the engine Reset Button Use the RESET button in the case of a sudden engine shutdown result...

Страница 16: ...reinserting the dipstick without rethreading it Remove the dipstick and examine the oil level If the oil level is at or below the minimum oil level refill the oil to the maximum oil level mark 4 Reins...

Страница 17: ...oil could shorten the engine s working life Do not mix different engine oils Handle and store the engine oil with care avoid getting dirt or dust into the engine oil Before the engine oil falls below...

Страница 18: ...e serious damage to the engine WARNING GASOLINE IS HIGHLY FLAMMABLE AND EXPLOSIVE UNDER CERTAIN CONDITIONS REFUEL IN A WELL VENTILATED AREA WITH THE ENGINE STOPPED DO NOT SMOKE OR ALLOW OPEN FLAMES OR...

Страница 19: ...CONNECT THE BATTERY WHILE THE GENERATOR ENGINE IS RUNNING DISCONNECT THE CABLES FROM THE BATTERY WHILE THE GENERATOR IS IN STORAGE 1 Loosen the two screws of the battery maintenance cover and remove...

Страница 20: ...rew the air filter cover and remove the filter 3 Clean the air filter with soap and water or solvent and squeeze dry do not wring out 4 Soak in clean engine oil 5 Squeeze do not wring out all excess o...

Страница 21: ...R AWAY FROM OPEN WINDOWS DOORS AND VENTS THESE OPENINGS CAN PULL IN GENERATOR EXHAUST EVEN WHEN YOU USE A GENERATOR CORRECTLY CO MAY LEAK INTO THE HOME ALWAYS USE A CO ALARM IN YOUR HOME IF YOU START...

Страница 22: ...A Remote Start 1 Open the fuel valve by turning the fuel knob to the OPEN position 2 Turn the power switch to the ON position 3 With the power switch in the ON position press the ON button of the remo...

Страница 23: ...he fuel valve by turning the fuel knob to the OPEN position 2 Turn the power switch to the ON position 3 Pull the starting grip slowly until it is engaged then pull it quickly Repeat until the engine...

Страница 24: ...ized service center to have the carburetor modified Two jets are available for high altitude operation altitudes of 5 000 to 6 500 feet 1500 2000m and altitudes of 6 500 to 8 200 feet 2000 2500m Conve...

Страница 25: ...ufficient to safely carry the generator s wattage See Chapter 1 2 Safety for more information The grounding system is not connected to the AC neutral wire 5 1 OUTPUT OVERLOAD AND OIL ALERT INDICATOR L...

Страница 26: ...und cable from the negative battery terminals 2 Connect the DC outlet to the battery terminals using the included charging cable Connect red lead to positive battery terminal and black lead to negativ...

Страница 27: ...ng them to the generator If an electrical appliance becomes abnormal sluggish or stops suddenly shut off the generator engine immediately and disconnect the appliance Most appliances require more than...

Страница 28: ...OVERLOADED AND THE RESET BUTTON WILL NEED TO BE PRESSED IF THE OVERLOAD INDICATOR LIGHT STAYS ON AFTER RESETTING THE GENERATOR STOP THE ENGINE WAIT FOR 5 MINUTES THEN RESTART IT NOTE For continuous o...

Страница 29: ...P position or press the OFF button on the remote control 3 Turn the fuel shutoff to the CLOSED position NOTE Make sure the fuel switch is in the CLOSED position when stopping transporting and storing...

Страница 30: ...o malfunction and can lead to serious injury Contact customer support if you have any maintenance questions General Inspection Tips Look for fuel leaks around the fuel tank fuel hose and fuel valve Cl...

Страница 31: ...ry 50 Hours Every 100 Hours Every 300 Hours Generator General Inspection Engine Oil Inspect Oil Level Change Air Filter Inspection Cleaning Sediment Cup Cleaning Spark Plug Inspection Cleaning Replace...

Страница 32: ...tandards regarding the emission control systems Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to this...

Страница 33: ...placement parts other than those from an authorized service centre will void the warranty Air Index Models certified for sale in California An Air Index Information label is applied to engines certifi...

Страница 34: ...g and the dipstick Then place an oil collection pan under the oil drain bolt 2 Remove the oil drain bolt 3 Drain into the oil collection pan completely Reinstall the oil drain bolt 4 Check the oil lev...

Страница 35: ...d store the engine oil with care avoid getting dirt or dust into the engine oil Before the engine oil falls below the safety margin the low oil alert system will automatically shut off the engine The...

Страница 36: ...ter will restrict air flow into the carburetor Clean and maintain the air filter regularly especially in dusty areas NOTE NEVER RUN THE GENERATOR WITHOUT AN AIR FILTER DOING SO WILL QUICKLY DEGRADE TH...

Страница 37: ...bottom of the spark plug TIGHTEN 1 2 TURN WHEN INSTALLING A NEW SPARK PLUG TIGHTEN 1 8 TO 1 4 TURN WHEN RE INSTALLING AN OLD SPARK PLUG 1 Remove the air filter access panel 2 Remove the spark plug cap...

Страница 38: ...spark plug with an improper heat range 7 5 SPARK ARRESTOR MAINTENANCE 1 Loosen the screws and remove the handle and rear housing 2 Take off the spark arrester from the muffler after the engine has co...

Страница 39: ...e red cable to the battery positive terminal and reconnect the black cable to the battery negative terminal 6 Re hook the battery belt and reinstall the cover NOTE If the battery is dead start the gen...

Страница 40: ...NS REFUEL IN A WELL VENTILATED AREA WITH THE ENGINE STOPPED DO NOT SMOKE OR ALLOW OPEN FLAMES OR SPARKS IN THE AREA WHERE THE GENERATOR IS BEING REFUELED OR WHERE GASOLINE IS STORED DO NOT OVERFILL TH...

Страница 41: ...he carburetor Transporting the Generator 1 Do not overfill the fuel tank No residual fuel on the neck of tank 2 Do not use the generator in the vehicle The generator should ONLY be used while in a wel...

Страница 42: ...rer s directions Adding a quality fuel stabilizer can keep gas fresh for up to a year 1 Year or More Drain off the gasoline from the fuel tank and store in a suitable container This will help prevent...

Страница 43: ...N Is the power switch in RUN Add the recommended oil Turn the power switch to RUN Clean readjust the gap and dry the spark plug Replace if necessary Is there enough oil in the engine Is the spark plug...

Страница 44: ...pliance for any fault Check the electrical appliance for any fault Is the DC circuit protector OFF Stop the engine and then replace or repair the appliance Repair or replace the appliance Turn the DC...

Страница 45: ...line Oil Capacity 18 fl Oz 0 55L Oil Type SAE 10W 30 GENERATOR Model Name eZV3200 Series Rated Frequency 60Hz Rated Voltage 120V Rated Current 23 3A Rated Speed 3600min 1 Rated Output Power 2 8kVA Max...

Страница 46: ...rminal Hourmeter Aux Winding 1 Aux Winding 2 Main Winding Battery 12V7 Ah Ignition Winding Trigger Warning Oil Sensor Spark Plug Ignition Fuse 6A DC Reset Stepper Motor 20A AC Breaker 25A AC Breaker A...

Страница 47: ...0 03 Relative humidity 100 correction factor C 0 04 Example Rated power PN 2 8kVA generator Altitude 1000m Ambient temperature 35 C Relative humidity 80 P Pn C 0 02 2 8 0 82 0 02 2 24kVA Altitude m A...

Страница 48: ...ct in components or workmanship during the three 3 year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstances This limited...

Страница 49: ...this Warranty we do not have the obligation to bear any transportation fees of any product to from an authorized Warranty Center Unauthorized alteration installation or any cause other than defects i...

Страница 50: ...designed built and equipped to meet the State s stringent anti smog standards Other States U S territories and Canada In other areas of the United States and in Canada your engine must be designed bui...

Страница 51: ...ture sensor Engine control module Fuel regulator Intake manifold Evaporative Fuel Tank Fuel Cap Fuel Hoses Vapor Hoses Carbon Canister Canister Mounting Brackets Fuel Strainer Fuel cock Fuel Pump Fuel...

Страница 52: ...ation Instructions Product registration is required for product support and warranty coverage You can register online at www energizergenerators com Once your registration is complete your receipt wil...

Страница 53: ...46 Enjoy Be sure to check energizergenerators com for updates regarding your generator...

Страница 54: ......

Отзывы: