14
PROBLEM: AC product will not operate, RED FAULT
light ON.
Battery voltage is too low. Recharge battery.
Possible cause
Solution
AC product(s) connected
are rated at more than the
inverter’s continuous
power rating; overload
shutdown has occurred.
Use a product with a power
rating less than the inverter’s
continuous power rating.
AC product is rated less
than the inverter’s
continuous power rating;
high starting surge has
caused overload
shutdown.
Product exceeds inverter’s
surge capability. Use a product
with starting surge power
within the inverter’s capability.
Battery is discharged.
Recharge battery.
Possible cause
Solution
Unplug inverter from DC socket
and allow to cool for 15 minutes.
Remove objects covering unit.
Move the inverter to a cooler
place. Reduce load if continuous
operation is required. Restart.
The inverter has over
heated due to poor
ventilation and has shut
down.