Installation
15.1
Location of the unit
•
The unit can be installed on any place outdoor which can carry heavy
machine such as terrace, housetop, ground and so on.
•
The location must have good ventilation.
•
The place is free from heat radiation and other fire flame.
•
There must be not obstacles near the air inlet and outlet of the heat pump.
•
There must be water channel around the heat pump to drain the
condensing water.
•
A place which is free from strong air blowing.
•
There must be enough space around the unit for maintenance.
Requirements
A
B
C
D
>500mm
>1000mm
>500mm
>1000mm
The heat pump must be placed upon a level and firm base that is suitable to
carry the weight of the unit e.g. a 100mm concrete base. The base must
provide for the unit to be sitting at least 150mm above the surrounding
ground. Allow for a slight tilt of the unit (3mm across the width running from
right to left as you face the fan(s)) to allow rain water run-off and any water
entering the unit to drain through the holes in the bottom of the unit.
The unit must be secured to its base using suitable fixings through the unit
feet. The rubber feet supplied with the unit must be used. Alternatively, there
are proprietary unit fixings available that include an adjustable steel frame
and legs with rubber mounting pads.
The unit must be fixed, stable and kept vertical during operation.
15.2
Condensate lines
Large amounts of condensation water, as well as melt water from defrosting
cycle can be produced. Provide good drainage at the installation area and
make sure water cannot run out onto paths or the like during periods that ice