Energie Aquapura 12 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

ENERGIE 

AIR WATER HEAT PUMP 
INVERTER UNIT 

 

 

Installation and Instruction Manual 

   EN 

Revision: 3 

Date: 06/11/20 

EN 60335-1; 

EN 60335-2-40. 

EN: 14825 

EN: 14511 

Model: 
Aquapura 12 

 Inverter R 8-12 

Aquapura 16 

 Inverter R 5-18 

Aquapura 16 T

 Inverter R 5-18 

Содержание Aquapura 12

Страница 1: ...AT PUMP INVERTER UNIT Installation and Instruction Manual EN Revision 3 Date 06 11 20 EN 60335 1 EN 60335 2 40 EN 14825 EN 14511 Model Aquapura 12 Inverter R 8 12 Aquapura 16 Inverter R 5 18 Aquapura...

Страница 2: ...Failure to follow these instructions may cause a fault of the Heat Pump resulting in electrical shock scald injury and or property damage Installer Before leaving the premises review this manual to be...

Страница 3: ...es 8 7 Principle of operation 9 8 Device description 9 9 Transport 10 10 Reception check 10 11 Dimensions 11 12 Overview 12 13 Performance 13 13 1 Heating Capacity 13 13 2 Electrical Power 13 13 3 Coe...

Страница 4: ...7 Timmer setting 26 16 8 Setup interface 27 16 9 Heat Pump Status 28 16 10 The operation of time setting 28 16 11 Manually Set of Electric Heating 29 16 12 Silent mode 29 16 13 Fault interface 30 17...

Страница 5: ...diagrams 44 22 1 Electrical connections inverter 8 12 44 22 2 Electrical connections inverter 5 18 46 22 3 Electrical connections inverter R 8 12 and inverter R 5 18 47 6 Appendix 5 Warranty 50 7 Appe...

Страница 6: ...h limited physical sensory or mental capabilities are to be allowed to control this equipment ensure that this will only happen supervision or after appropriate instructions by a person responsible fo...

Страница 7: ...wer When there is something wrong or strange smell the power supply needs to be shut off to stop the unit Continue to run may cause electrical short or fire Move and repair Meaning Entrust When the he...

Страница 8: ...Please check the installation basement in a period one month to avoid any decline or damage on the basement which may hurt people or damage the unit Switch off the power Please switch off the power fo...

Страница 9: ...uropean Standards Always concerned with the quality and performance of our products we strive continuously to improve them Therefore we reserve to the right to modify at any time the information descr...

Страница 10: ...t pump features Inverter air source water heat pump is a kind of high efficiency energy saving and environment friendly equipment which is mainly used for house warming This series of heat pump unit o...

Страница 11: ...valve low noise scroll compressor condenser and the control unit In the case of low ambient temperatures air humidity may accumulate on the evaporator in the form of frost impairing the heat transfer...

Страница 12: ...e recommended tools to transport the equipment while it is still on the pallet can be forklift or pallet When transporting the unit make sure that you lift it only from the bottom and always with the...

Страница 13: ...mensions Aquapura 12 Inverter R 8 12 Aquapura 16T Inverter R 5 18 and Aquapura 16 Inverter R 5 18 A Water outlet 1 1 4 B Water inlet 1 1 4 C Electrical connections A Water outlet 1 B Water inlet 1 C E...

Страница 14: ...a 16 T inverter R5 18 Maximum distance between display and outdoor unit 100m DISPLAY Control Interface DISPLAY Control Interface Water outlet 1 Water inlet 1 Air outlet horizontal Air outlet horizonta...

Страница 15: ...ENERGIE Page 13 13 Performance 13 1 Heating Capacity 13 2 Electrical Power 13 3 Coefficient of performance Water temperature 30 35 C...

Страница 16: ...lass 55 C A A SCOP 2 water 55 C s 3 86 151 3 72 146 Maximum power power current kW A 4 6 21 5 7 2 33 2 7 2 12 Water temperature Heating C 60 60 Cooling C 7 7 Range of external temperature Heating C 25...

Страница 17: ...crete base The base must provide for the unit to be sitting at least 150mm above the surrounding ground Allow for a slight tilt of the unit 3mm across the width running from right to left as you face...

Страница 18: ...water loop and the water level in the tank must be at least 0 5 meter higher than the top point of the water loop The flow switch is installed inside of the heat pump check to ensure that the wiring...

Страница 19: ...at pump For the initial charging and backfill of the system usually normal tap water with a pH value of 7 8 can be used as long as the water is not highly corrosive chloride content 150 mg l or hard 1...

Страница 20: ...able is for reference please use anti freezing water according to the real condition of the local climate 15 8 Temperature probes temperature vs K NTC 5K e NTC 10K NTC 50K 45 40 35 30 25 20 15 10 5 0...

Страница 21: ...electrical installation must be performed in accordance with local regulations and by a qualified professional Electrical connections inverter R 8 12 Electrical connections Inverter R 5 18 and Inverte...

Страница 22: ...afely And the external earth wire must be in order The creepage protection device must be settled in accordance with the relevant national technical standards for electronic equipment The power wire a...

Страница 23: ...llation is through an ambient thermostat Your installation location is extremely important following a series of requirements as we can see in the figure below The thermostat must be installed an inte...

Страница 24: ...front panel contains the display and keyboard which when pressed allow to perform all of the controller programming operations 1 Power on interface 2 Starting up interface Remark the wire controller c...

Страница 25: ...nabled 6 Setup key Click this key to check the Unit status Time factory parameter Temperature curve Timer setting Mute setting 7 Fault icon This Icon will flash when there is an error shown up then th...

Страница 26: ...6 4 Startup and shutdown the unit As the main interface shows In shutting down interface on off key is in gray status press on off key can start up the machine In starting up interface on off key is i...

Страница 27: ...go into hot water heating mode interface 5 Tapping hot water cooling mode icon then the display will come to hot water cooling mode interface 16 6 Setting of target temperature Press to set the targe...

Страница 28: ...Return key Tapping this key can back to the main interface Delete key Tapping this key to undo the last action Enter key Tapping this key can save you action and back to the main interface 16 7 Timme...

Страница 29: ...ue of the variables read by the controller eg pressure temperature etc 5 Time Set time 6 Silent mode Activate and set period in silent mode 7 Temperatur e curves Evolution of inlet and outlet temperat...

Страница 30: ...s Click the up and down key to set the month Click the up and down key to set the day Click the up and down key to set the year Click the up and down key to set the hour Click the up and down key to s...

Страница 31: ...1 Electric Heating ON 2 Electric Heating OFF In the heating mode press the key to turn on and the key to turn off the electric heating NOTE Electrical kit is not provided with equipment 16 12 Silent...

Страница 32: ...icon on the main interface and the interface display is as follows Note Fault code Fault name Occurrence time of the fault day month and year hour second s Click this key to clear all fault records th...

Страница 33: ...temperature In these circumstances the setpoint will be calculated according to the following parameters Parameter Descripition Value R02 Heating mode setpoint user R29 ON compensation in low outdoor...

Страница 34: ...R23 In these circumstances the setpoint will be calculated according to the following parameters Parameter Description Value R01 DHW mode setpoint userr R29 ON compensation in low outdoor temperature...

Страница 35: ...or short circuit Check or change the pressure Sensor or pressure Suction Pressure Sensor Fault PP2 The pressure Sensor is broken or short circuit Check or change the pressure Sensor or pressure EVI In...

Страница 36: ...ontact 1 Change a new fan motor Check the wire connection and make sure they are in good contact Fan motor speed controller failure E081 Communication failure between the control board and the fan spe...

Страница 37: ...acking Phase F15 The input voltage lost phase Check and measure the voltage adjustment IPM Current Sample Fault F16 IPM sampling electricity is fault Check and adjust the current measurement Sensor Fa...

Страница 38: ...ENERGIE Page 36 18 1 Main board interface...

Страница 39: ...13 The low preesure switch 1 19 AI DI12 The high preesure switch 1 20 AI DI11 Temperature of the EVI outlet of system 1 21 AI DI10 Temperature of the EVI inlet of system 1 22 AI DI09 System1 Antifreez...

Страница 40: ...ng and Additional Information Failure Possible causes for the failure Solutions BC does not work display without information 1 Power supply failure 2 Circuit breaker off 3 Power cable not properly con...

Страница 41: ...temp reset the return water temp clean the water filter and discharge the air in water loop 2 compressor contactor broken 3 power cable loose 4 5 protection on compressor wrong setting on return wate...

Страница 42: ...ating 3 Safety valve A1 Cold water inlet DHW 4 Expansion vessel B Central heating radiators floor heating or fan coils 5 Filter C Hot water outlet DHW 6 Valve non return BT Buffer tank 7 Water tank DH...

Страница 43: ...sure meters water temperature meter drainage etc 21 1 Central heating cooling The heat pump will heat the water so that the water can be used for heating or cooling Normally for heating the water is k...

Страница 44: ...PORTANT The control of the circulating pump P1 must be carried out separately 21 3 Central heating cooling with buffer tank DHW IMPORTANT The heat pump automatically manages the three way valve The co...

Страница 45: ...43 21 4 Central heating cooling DHW IMPORTANT The auxiliary control unit automatically manages the heat pump and the three way valve depending on the temperature in the DHW tank and the ambient thermo...

Страница 46: ...damage to the controller and loss of warranty WARNING The digital inputs Remote Heat Cool DHW ON OFF and Heat Cool ON OFF are inactive by default giving priority to settings made through the console T...

Страница 47: ...function dry contact voltage free contact 24 25 Enable or disable Heat Pump operation in Hot Cold mode via digital input dry contact voltage free contact 26 27 Output for 3 way DHW valve DHW function...

Страница 48: ...ontroller and loss of warranty WARNING The digital inputs Remote Heat Cool DHW ON OFF and Heat Cool ON OFF are inactive by default giving priority to settings made through the console To enable digita...

Страница 49: ...via digital input dry contact voltage free contact 22 23 Output for 3 way DHW valve DHW function active output voltage is 0V 24 25 DHW circulation pump output DHW function activates 230Vac output vol...

Страница 50: ...do the following steps 1 Press key to access the heat pump settings 2 Press 4 Factory 3 Enter the password 066 4 Press System 5 Change the setting from Wire Controller to Enable To change the configur...

Страница 51: ...ting mode DHW ON OFF Activate DHW function o Open contact BC with inactive DHW function o Closed contact BC with active DHW function HEAT COOL ON OFF Enable or disable BC operation in Hot mode or in C...

Страница 52: ...ot reason for an extension of its term Warranty Exclusions The warranty ceases to be effective when the apparatus is no longer connected used or assembled in accordance with manufacturer instructions...

Страница 53: ...mproper use of the apparatus The warranty lapses if it is transferred to another owner even if within the guarantee period The warranty lapses if this certificate is incorrectly filled in if it is vio...

Страница 54: ...ss Telephone N Heat Pump Details Model Serial N Date Installed Date of commissioning Please sing below and return to our Technical Dep Via fax 351 252600239 email energie energie pt or post to the add...

Страница 55: ...____kW Hot Water Preparation Hot water cylinder size _____________________ liters Make type _____________________ Heat Exchanger Surface Area ________________ m2 Electric Heating _______________ kW Ac...

Страница 56: ...maintenance of the unit that are not addressed in this manual or if you feel that something in the manual is unclear please contact us ENERGIE EST Address Zona Industrial de La ndos Lote 48 4570 311 L...

Отзывы: