17/28
2. CG mode
1. After selecting the CG mode of operation, the rated voltage must be set: press ROLL to scroll
through all options, then press ENTER to confirm and move on to the next selection.
2. For the current setting, press ROLL to increase the current value by 10 A increments, then press
ENTER to confirm and move on to the next step, the unit.
3. To select the unit, press ROLL to increase the current value in increments of 1 A. Press ENTER to
confirm and proceed to charge or desulphation selection.
4. TIME selection. Press ROLL to decrease the timer by 1-hour increments, then press ENTER to finish
programming.
5. Programming ends and the charger enters a waiting state: connect a battery and press the MODE
button to ROLL to start the charge/sulphation profile.
3. BC mode
1. After selecting the BC work mode, you need to set your battery type: press ROLL to select a value:
• Choose BA1 for lead-acid batteries.
• Choose BA2 for lead-gel.
Press ENTER to confirm
2. Then you need to program the rated voltage: press ROLL to scroll through all the options, then
press ENTER to confirm. Proceed to select the curve type.
3. Press ROLL to select the desired curve:
• Select CU1: IUIa curve plus equalisation and maintenance.
• Select CU2: IU1U2ob curve.
Press ENTER to confirm.
4. Now select the capacity value: press ROLL to decrease the displayed value in steps of 50 Ah. Select
a value closest to the desired capacity value, then press ENTER.
5. Once you have set the capacitance value, programming is complete. If no battery is connected,
the charger will go into standby mode until a battery is connected.
As soon as a battery is connected, the charger will start the set program.
If problems or errors occur during the adjustment procedure, turn off the charger using the
rotating ON-OFF switch.
Turn on the charger again by pressing and holding the MODE button and restart the
adjustment procedure from the beginning.
4. S/S function
The multi-charger is equipped with an S/S input which, when switched on, allows control of the
charger by means of a low voltage input.
When the S/S input is closed, the charger can work. When the S/S input is open, the power generator
is paused. As soon as the charging is paused, you can restart by closing the S/S input again.
The multi-charger is also equipped with a Start/Stop for battery functions. This function resets the
charger when a battery is disconnected and the charger will place itself back on hold.