WARNING

 

 

General Precautions 

The  output  beam  from  the  EQ-400  should  be  blocked  when  not  in  use  with  an  electronic 

shutter or other appropriate beam blocking device.  Due to the possibility of generating ozone 
with some models of EQ-400 when ambient oxygen is exposed to short wavelength light, the 

beam should always be enclosed in an appropriate beam pipe, tube, or enclosed space.  We 
suggest purging any beam transport space with dry nitrogen gas. 

The  EQ-400  source  must  also  be  cabled  correctly  and  connected  to  a  power  source  with  a 

protective earth ground prior to operation. 

Refer  to  the  Installation  section  of  this  manual  in  Chapter  3  for  details  of  the  facilities 

connections. 

There are no user-serviceable parts inside the EQ-400.  For any problems encountered during 
operation,  please  contact  Energetiq  Technology  for  assistance.   

If  there  is  a  component 

failure, do not attempt to open the Power/Control Unit or Lamp House enclosure of 
the EQ-400.  

No  regular  maintenance  is  required  for  the  EQ-400.    Any  service  to  the  system  must  be 

performed  only  by  factory  authorized  and  trained  technicians.    To  avoid  injury,  under  no 
circumstances  should  the  user  open  or  modify  the  Lamp  House  or  Power/Control  Unit 

enclosure. 

The unit must not be operated if the covers are removed or it is defective in any way.  Contact 

Energetiq if any problems with the equipment are suspected. 

The EQ-400 utilizes a quartz lamp containing a high-pressure gas fill.  Explosion of 
the  lamp  and  possible  injury  from  flying  fragments  can  occur  if  the  lamp  is 

mishandled.   

Do  not  open  the  enclosure  of  either  the  Lamp  House  or  the  Power/Control  Unit.  
Dangerous  invisible  infrared  laser  beams  and  hazardous  voltages  exist  inside  the 

Lamp  House.   

Opening  the  chassis  both  voids  the  warranty  and  exposes  the  user  to 

dangerous radiation and hazardous voltages. 

The EQ-400 utilizes an  internal Class 4 IR laser 

capable  of  causing  severe  injury  to  eyes  or  skin.  

Do  not  open  or  attempt  to  service  this  unit.  
Contact  Energetiq  regarding  any  problems  with 
the unit. 

 

Содержание LDLS EQ-400

Страница 1: ...Model EQ 400 LDLS Laser Driven Light Source Operation Manual Revision 7 April 2018 Part Number DOC 7388...

Страница 2: ...nical information including drawings schematics and specifications contained in this manual are the property of Energetiq and shall not be reproduced in whole or in part without the written consent of...

Страница 3: ...EU Declaration of Conformity...

Страница 4: ......

Страница 5: ...ifications 10 System Description 12 Power Control Unit PCU 13 Lamp House 14 Chapter 3 17 Installation 17 Unpacking 17 Installation Procedure 17 Chapter 4 21 Operation 21 Starting 21 Stopping 21 Manual...

Страница 6: ......

Страница 7: ...ace prior to energizing the unit All interlocks must be satisfied prior to operation failure to do so may lead to hazardous conditions The EQ 400 emits dangerous levels of UV radiation Even short expo...

Страница 8: ...pt to open the Power Control Unit or Lamp House enclosure of the EQ 400 No regular maintenance is required for the EQ 400 Any service to the system must be performed only by factory authorized and tra...

Страница 9: ...lasma that radiates in the UV as well as the visible bands A Class 4 laser is located in the Power Control Unit enclosure The optical configuration of the Lamp House ensures that the direct laser beam...

Страница 10: ...following safety labels appear on the product Figure 1 shows the location of each label on the EQ 400 system UV Hazard warning label indicates hazardous levels of UV light are present Manufacturer s...

Страница 11: ...or Reference source not found 5 Hazard warning label indicates that a laser hazard is present Protective housing label warns of an enclosed laser radiation hazard Protective housing label warns of an...

Страница 12: ...6 EQ 400 Operation Manual Rev Error Reference source not found Aperture Label Manufacturer s Identification label UV Hazard Warning Label Hazard Warning Label Protective Housing Label...

Страница 13: ...ith interlocks to prevent operation of the device when any of the following conditions are present 1 A remote interlock is open 2 Lamp House cover not installed 3 Laser fiber not connected to Lamp Hou...

Страница 14: ...Any suitable normally open contact or solid state switch can operate the interlock circuit The contact or switch should be rated for 8mA minimum at 5VDC The interlock circuit must be connected to enab...

Страница 15: ...nclude Very high brightness across complete spectrum 190nm through visible and beyond Eliminates need for multiple lamps replaces D2 Tungsten Xenon Arc Simplified optical system Excellent spatial stab...

Страница 16: ...nit 133 x 483 x 584 mm 5 2 x 19 0 x 23 0 in Weight Lamp House 2 7 kg 6 0 lb Power Control Unit 18 8 kg 41 5 lb Utility Requirements Electrical 200 240 V 50 60 Hz 7A 1700 W max Purge gas clean dry nitr...

Страница 17: ...85 4 wire full duplex Connector Male 9 pin d sub Termination 120 ohms across receiver input pins 2 and 7 Interface protocol see Chapter 4 Port settings 9600 bps 8 data bits 1 stop bit no parity no han...

Страница 18: ...fiber permanently attached to the PCU The following sections provide descriptions of the system components and controls and give an overview of their functions Refer to the Installation section of th...

Страница 19: ...is ON and laser light is being produced within the Lamp House REMOTE System is in remote control mode LASER OVERTEMP Laser internal temperature too high LASER FAULT Laser module internal fault PCU FAU...

Страница 20: ...l Connector 9 pin D sub Provides various power and control signals to from the Lamp House module No other connector or cable may be used with the EQ 400 other than the one supplied RS 485 Connector 9...

Страница 21: ...ouse Assembly Output Window also on opposite side Laser radiation in excess of Class 1 exposure limits is emitted from these apertures Control Connector to PCU Nitrogen Purge Inlet Laser ON Indicator...

Страница 22: ...eding Class 1 emission limits is emitted from the output apertures Nitrogen Purge Inlet Outlet These are the fittings for the required nitrogen purge gas With no purge ozone will form from atmospheric...

Страница 23: ...amp House due to the length of the interconnecting cable See drawing OTD 8198 in Appendix A for dimensional details Note The PCU weighs 18 8 kg 41 5 lb A two person lift is recommended Use care when m...

Страница 24: ...Power Control Unit to the Lamp House 5 Connect nitrogen purge gas to the 4mm push to connect fittings on the Lamp House 6 Connect cooling water to the 8mm Swagelok fittings on the Lamp House 7 Connect...

Страница 25: ...n when ON LASER ON 2 Pulled to digital common when ON LAMP MODULE FAULT 3 Pulled to digital common when OK float on FAULT CONTROLLER FAULT 4 Pulled to digital common when OK float on FAULT ISOLATED 5V...

Страница 26: ...20 EQ 400 Operation Manual Rev Error Reference source not found Figure 5 Remote Interface Schematic...

Страница 27: ...LED will light Laser light is now present in the Lamp House 5 Within several seconds the igniter will be turned on automatically and the plasma will ignite The LAMP ON LED will light To avoid thermal...

Страница 28: ...to clear the fault The lamp can then be started normally by turning the switch to OPERATE Serial Interface The RS 485 serial interface is provided for user adjustment of laser operating power in order...

Страница 29: ...Query bulb operating time Bulb time XXXX secs Z Zero bulb operating time Send z within 10 sec to confirm z Confirm zeroing of bulb time Bulb hours zeroed flash saved L Query laser operating time Lase...

Страница 30: ...ltage 1 out of range 0 OK 5 Laser current source 1 fault 0 OK 6 Lamphead temperature 1 overtemperature 0 OK 7 PCU temperature 1 overtemperature 0 OK 8 Lamphead interlock 1 open 0 OK 9 External interlo...

Страница 31: ...erence source not found 25 A p p e n d i x A ENGINEERING DRAWINGS The following engineering drawings are included for reference Drawing number Revision Title OTD 8159 1 EQ 400 Lamp Housing Outline OTD...

Страница 32: ...26 EQ 400 Operation Manual Rev Error Reference source not found...

Страница 33: ...version 23 January 2017 1 Initial release 08 February 2017 2 Added protective housing label and additional safety information 10 February 2017 3 Updated labeling information 7 September 2017 4 Miscell...

Страница 34: ...28 EQ 400 Operation Manual Rev Error Reference source not found...

Страница 35: ......

Страница 36: ...nical information including drawings schematics and specifications contained in this manual are the property of Energetiq and shall not be reproduced in whole or in part without the written consent of...

Отзывы: