17
EG-SMS PROGRAMMABLE POWER OUTLET STRIP
WITH GSM INTERFACE
All brands and logos are registered trademarks of their respective owners
SLLL– low temperature limit, in degrees C. S is sign – or +.
Example: -001 equals to -1 degree C.
SHHH – high temperature limit, in degrees C
F – LOCKER sensor is controlling the socket. 1 – yes, 0 - no
G – Socket control, when LOCKER is opened (contact is open).
1 – Socket ON, 0 – Socket OFF
H - WATER sensor is controlling the socket. 1 – yes, 0 - no
G – Socket control, when WATER is present (contact is closed).
1 – Socket ON, 0 – Socket OFF
Response SMS:
500A0B0CSLLLSHHH0F0G0H0I
Example SMS:
Gembird15000+03400000000
This command controls the Socket 1 ON when temperature drops
below 0 or rises higher 34 deg C, and controls it OFF when temperature
returns within these limits.
PASSWORD510A
A – Socket number , 0 for Socket 1, 1 for Socket 2 , etc.